MIEN6208 Series Management Industrial Ethernet Switch
MIEN6208: 8 copper ports.
The side panel of MIEN6208 series switches is equipped with a 6-position
lock terminal with 5.08mm pitch as below:
Power input
The DC power supply models of MIEN6208 series switches support
DC12V-44V power supply by default, and users can DC48V, support dual
power input, the two power sources are mutually backup.
The AC power supply models of MIEN6208 series switches support
DC110V~370V and AC85V~264V power supply.
For AC models, V can only be input from V1+ and V1-, V1+ connects to
live wire L, and V1- to neutral wire N. Do not connect from V2+, V2- and pay
attention to safety to prevent electric shock.
Power failure alarm output
MIEN6208 series switches support alarm function and have normally
closed nodes. When the switch is working normally, the normally closed node
is disconnected.
When the system is powered off, the port is offline, or the network storm
alarms, the normally closed node is closed. The recommended switching load
capacity of the relay is 1A(24VDC). The user can use the relay contact output
to connect other sound and light alarm devices.