2. Carry the bucket to a sink of floor drain. Keeping a hold of the handle and placing a hand under the
bucket and then leaning the container forward, empty the water content.
3. Put the drain bucket back in the dehumidifier.
► METHOD 2 – Gravity Draining Using a Hose
The drain hose is not provided, therefore the user must
purchase one. The hose thread should have an outer
diameter of 27 mm (11/16 in) and a pitch of 11.5 TPI.
1. Remove the drain bucket.
2. Thread the drain hose onto the nozzle and make sure it
is secure.
3. Put the bucket back in the unit. Make sure the drain
hose goes through the bucket's drain hole and is going
downward. Lead the hose to a floor drain, then cover
the hole with a lid. Note that drain hose should not be
pressed, otherwise the water may not be able to properly
drain out. Before disconnecting the drain hose from the
unit, be sure to place a receptacle to collect water that
may drip from the nozzle.
► METHOD 3 – Pump Draining (for models with pump only)
1. While pressing down on the plastic collar of the pump
port, pull out the water stopper.
2. Insert the drain hose into the pump port.
3. Lead the other end of the hose to a floor drain, a water
container, or out a basement window to the outdoors.
NOTES :
▪ If using the pump draining method, the unit must be set to run in Pump mode. Please refer to the
Operation Guide: Button Functions section of this instruction manual for more information.
▪ The maximum distance and elevation at which the drain hose can extend from the unit is 5 meters.
Exceeding this distance may damage the pump or cause leaks.