Majestic 42MCUFD SERIES Manual de instruções de instalação e funcionamento - Página 14

Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Lareira de interior Majestic 42MCUFD SERIES. Majestic 42MCUFD SERIES 20 páginas. Unvented vent-free fireboxes

OPTIONAL EqUIPMENT

BRASS OR CHROME TRIM

Optional brass trim kits can be used with unit when installed as a free standing fireplace with wood surround.

OPTIONAL WIDE CANOPY

The optional wide canopy can be installed. See installation instructions provided with kit.
FORCED AIR KIt (BLOTMC)
If you are installing the forced air kit, Model BLOTMC, on 36MCUFD or 42MCUFD models, see the installation instructions
provided with the kit for electrical wiring requirements, or the blower installation section. The firebox must be connected
to main power supply at time of firebox installation. The blower must be installed prior to the installation of the vent-free
heater. The electrical connections must be made before the firebox is framed and enclosed in the finished walls.
Electrical connections should only be performed by a qualified, licensed electrician,
main power must be off when connecting to main electrical power supply or performing
service.
the blower when installed, must be electrically grounded in accordance with local
codes or in the absence of local codes, with the National Electrical Code ANSI Z.223.1/
NFPA 70.
this fireplace has a three-prong, grounded electrical plug. this plug helps protect
you against electrical shock. Only connect plug to a properly grounded, three-prong
receptacle. Do not cut or remove the grounded prong from this plug.
Never attempt to service heater while it
is plugged in, operating, or hot. Burns
and/or electrical shock could result.
IMPORTANT: Always check local building
codes. The installation must comply with local
regulations as well as the national electric codes.
110/115
V.A.C.
14
Fan Switch
OFF
Black
ON
White
Green
Figure 16 - BLOTMC Wiring Diagram
Any of the original wire as supplied with the fireplace must
be replaced. Contact dealer for proper replacement wiring
harness. (see parts list for part number). 120 volts, 60Hz,
1 amps.
Electrical power cord (plug) can be routed to exit the
36MCUFD/42MCUFD on either the left side or the right side.
Remove cord protector from side of unit, route power cord
through hole opposite side. Reinstall cord protector.
Thermostat
Control
Black
Blower
Motor
26D4750