Majestic FSUV30 Instruções de instalação e de utilização para os proprietários - Página 6

Procurar online ou descarregar pdf Instruções de instalação e de utilização para os proprietários para Lareira de interior Majestic FSUV30. Majestic FSUV30 16 páginas.

FSUV20/30 Vent Free Gas Heater

Run Gas Line

If gas piping from the source to the heater location has
not been accomplished, install the required pipe. Con-
sult local plumbing code to assure proper pipe size.
The gas pipeline to be brought in through the rear or
the base of the heater.
NOTE: The gas line connection can be made with
properly tinned 3/8" copper tubing, 1/2" rigid pipe or an
approved flex connector, then reduced to 3/8" to the
heater. Because some municipalities have some addi-
tional local codes, it is always best to consult your local
authority. Consult the current National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
Always check for gas leaks with a mild
soap and water solution. Do not use an
open flame for leak testing.
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to pro-
f i r e - p a r t s . c o m
vide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved
fittings. Always provide a union when using black
iron pipe so that gas line can be easily disconnected
for burner or fan servicing. See gas specification for
pressure details and ratings. NOTE: If flex connector is
used, it must be kept inside of the heater. (Fig. 3)
1/2" Gas Supply
1/2" x 3/8" Shut-Off Valve
FP297
Fig. 3 Typical gas line installation.

Remote Switch

Install ON/OFF switch assembly on either the rear right
or left side of the FSHUV gas fireplace.
1. Remove the screw at the back of the cabinet top
either n the left or the right side of the fireplace.
2. Position switch assembly onto the back of the fire-
place, then fasten two screws as shown in Figure 4.
3. Attach wiring under the clips n the rear casing (Fig.
4) and install wiring through the rear opening of the
fireplace before connecting to the valve. (Fig. 5)
6
Installation
3/8" Nipple
3/8" Union
3/8"
Nipple
FP297
INSTA VENT FREE
R MODEL GAS SUPPLY
8/24/96
ON/OFF Switch
Assembly
Clips
Fig. 4 Position the switch assembly on back of stove.
OFF
Fig. 5 Remote switch wiring.

Slide the Heater in Place

With the fan installed, gently slide or lift the heater to
FP1586
the desired location.

Level and Secure the Heater

valve switch wire
Make sure heater is level. Shimming may be required.
Screw
(through
existing
hole)
Wiring for Mil-
livolt Gas Valve
FP1588
������
������ ����
FP1586
10001784