A. General Introduction
1.1 Brief Introduction
The Electric Convection Oven uses hot air circulation mode, so the temperature up quickly and
heat evenly. The oven also has timer and thermostat, so the user can accord needs adjust the
time and the temperature. The oven has steam function, and the operator can add the steam to
the food. The glass of the door has two layers, so it is beautiful and it can insulate heat. There
is a micro-active switch beside the door. When open the door, the fan will stop turning. This
can avoid the hot air hurt anybody. The oven is adapted to place in front of the supermarket
and fast-food restaurant.
1.2 Technology Parameter
Dimension: 834×796×572mm
Voltage: 230V/50Hz
Power: 6.4KW
Water Pressure: 50~200kPa
1.3 Safety Attention
1. The oven must be placed on an even surface, and the both sides far away from the inflammable
materials at least 10cm. The user should install a suitable power switch and fuse breaker near
the machine in order to normal maintenance. Don't put anything in front of the switch, easy to
operation.
2. All the users must follow the safety electric standard. Before using, make sure the power
voltage corresponds to that stated on the data plate, and well ground connection.
3. Only use the oven under safety conditions. If there is any trouble, must maintain it at once.
4. The oven must be test before using.
5. The maintenance and the installation must be operated by professional people. Before carrying
out any type of maintenance it is necessary to disconnect the electric power supply and wait for
the appliance cool down.
6. During the operating, don't touch the oven in case of scald.
B. Installation
2.1 Electrical Connection
1. The connection to the electric power supply must be done according to the standard.
2. Before installation, make sure the power voltage corresponds to that stated on the data plate.
2.2 Water Connection
1. Use a 1/2''dia.water tube connects to the magnetic-valve, and fixed firmly in case of water
leakage.
2. Let a certain quantity of water flow to clean the duct. The water must have a hardness between
0.5°-5°F(this is in order to reduce the formation of limestone deposits )and the water
pressure between 50~200kPa.
2