Maintenance Continued
Cleaning the valves – Basin Taps, Bath Taps, Bath Fillers and Bath Shower Mixers
We advise that your fitting is regularly services in hard water areas to maintain optimum
performance (see map of Hard Water Regions in the UK on page 15)
Isolate both hot and cold water supplies
to the tap by either:
• Turning the water supply off at the
mains or stopcock
• Turning off the isolation valves to the
tap
1. Remove the cap at the rear of the
handle to reveal the grub screw
2. Unscrew the grub screw and pull
handle upwards from the shroud
3. Unscrew the shroud and using a
suitable spanner, remove the valve
from the tap body
4. Using a suitable cleaner, clean the
valve and the seating inside the tap
body
5. If necessary, replace the valve
Please visit
www.Bristan.com/sparesfinder in order
to find spare parts for this product.
6. Replace the valve into the tap body
and tighten fully using a suitable
spanner
7. Replace handle assembly
8. Turn on water supply and check for
leaks.
9. Contact our helpline if the problem
persists 0330 026 6273