Specifications
4.1

Approvals, tests and conformities

8
Parameter
Signalverhalten
Accuracy
Measurement speed
Operating temperature range
Temperature error
Ambient
Medium
Storage
Electrical safety
Protection
Electromagnetic compatibility (EMC)
Noise suppression
Noise immunity
Table 2: Input value
Parameter
Nominal pressure rel./abs.
Permissible overpressure
Burst pressure
DIM 20 conforms to the Pressure Equipment Directive
(97/23/EC).and the EMC Directive (2004/108/EC).
Value
≤ ± 0,5 % FSD
Deviation according to BSFL (includes
non-linearity, hysteresis and reproduci-
bility)
5/s
≤ ± 0,5 % FSD/10 K in compensated
range 0 °C to +70 °C
-20 °C to +45 °C
-20 °C to +125 °C
-30 °C to +80 °C
IP 51 EN 60529
According to EN 61326
According to EN 61326
Value [bar]
-1...0
1
3
3
4
4
400
700
650
1.200
700
1.500
DIM 20