Bristan IRSD1-BN Instruções de instalação e manual do utilizador - Página 7
Procurar online ou descarregar pdf Instruções de instalação e manual do utilizador para Dispensador Bristan IRSD1-BN. Bristan IRSD1-BN 16 páginas. Infrared automatic soap dispensor
Também para Bristan IRSD1-BN: Instruções de instalação e manual do utilizador (16 páginas)
Installation
4. Attach Pump to Bottle
Ensure the dispenser tube is located
inside the bottle and push the pump
down firmly onto the bottle until a
loud 'click' is heard.
To remove the pump from the bottle
press the release button in on the
side of the pump and pull the pump
from the bottle.
This product should not be used
to dispense alcohol-based hand
sanitizer gels or liquids.
5. Connect Sensor Cable and
Dispenser Cable
Connect the sensor cable from the
spout to the sensor cable on the
pump. Push the two connections
together and tighten the connecting
ring to ensure the two connections
are locked together.
Connect the dispening cable from
the spout into the top connection on
the pump.
Push the threaded connection of the
dispensing cable into the connection
on the pump and tighten the nut
ensuring it is fully tightened.
A suitable spanner may be used to
tighten the nut.
6. Place Pump into Bracket
The pump has a cut out section
which the wall bracket slots into.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Pump
Dispenser
Tube
Dispenser
Cable
Bottle
Power
Cables
Senser
Cables
7