Majestic fireplaces UVS43 Manual de instalação e funcionamento do proprietário - Página 7

Procurar online ou descarregar pdf Manual de instalação e funcionamento do proprietário para Aquecedor a gás Majestic fireplaces UVS43. Majestic fireplaces UVS43 20 páginas. Vermont castings vent-free gas room heaters homeowner's installation and operating manual

Parts Identification
Nailing
Flange
Gas
Line
Access
FP443
Fig. 6 Parts identification.
Gas Specifications
Model
Fuel
Gas Control
UVC36RN
Natural
Millivolt Hi/Lo
UVC36RP Propane
Millivolt Hi/Lo
UVS36RN
Natural
Millivolt Hi/Lo
UVS36RP
Propane
Millivolt Hi/Lo
UVC43RN
Natural
Millivolt Hi/Lo
UVC43RP Propane
Millivolt Hi/Lo
UVS43RN
Natural
Millivolt Hi/Lo
UVS43RP
Propane
Millivolt Hi/Lo
UVC36 / UVS36 / UVC43 / UVS43
Certified To
ANSI Z 21.11.2a-2003
Unvented Room Heaters
Units: B42A00, B42B00, D42A00, D42B00, B41AS0,
B41BS0, D41AS0, D41BS0

Gas Inlet and Manifold Pressures

Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure
20000135
Catalytic Filters
(Behind Grille)
UVC
Top Louvre
Screen Panel (UVS)
Glass Panel (UVC)
Logs and Burner
Firebox
Bottom Louvre
(Bottom Access Door)
(Controls behind louvre)
GF443 UVC
(from GF379)
2/11/97
Max.
Min.
Input
Input
B.T.U.H. B.T.U.H.
25,000
17,500
25,000
18,750
25,000
17,500
25,000
18,750
33,000
23,100
33,000
24,750
33,000
23,100
33,000
24,750
Natural
LP
5.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5" w.c
10.0" w.c.
Majestic Fireplaces
UVC / UVS Vent-Free Heaters
®

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration from elevations up to
4,500 feet (1,370m) above sea level.
Nuisance outages may occur at altitudes above
4,500 feet (1,370m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/or
ODS pilot. Monthly inspection and cleaning is
recommended for altitudes above 4,500 feet
(1,370m)
For elevations above 4,500 feet (1,370m), instal-
lations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.
The installation of your Majestic Fireplaces room-
heater must conform with local codes, or in the
absence of local codes, with National Fuel Gas
Code, ANSI Z223.1/NFPA 54 — latest edition. (EX-
CEPTION: Do not derate this appliance for altitude.
Maintain the manifold pressure at 3.5 inches w.c.
for Natural Gas and 10 inches w.c. for LP gas.)

Gas Supply Pressures

This heater must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure equal to or less than 1/2 psig (3.45
kPa).
The heater and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.45 kPa).

Connect the Gas Line

If gas piping from the source to the heater location has
not been accomplished, install the required pipe. Con-
sult local plumbing code to assure proper pipe size.
The gas pipeline can be brought in through the right or
left side of the heater, as well as the bottom. Knockouts
are provided at convenient locations to allow for the gas
pipe installation and testing of any gas connection. It is
most convenient to bring the gas line in from the right
side, as this allows fan installation or removal without
disconnecting the gas line.
NOTE: The gas line connection can be made with
properly tinned 3/8" copper tubing, 1/2" rigid pipe or an
approved flex connector, then reduced to 3/8" to the
heater. Because some municipalities have some addi-
tional local codes, it is always best to consult your local
authority. Consult the current National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
7