MAINTENANCE and ADJUSTMENTS
Low LBs
6 . 0
2
LBs
KGs
High LBs
High KGs
cover from the L.E.D. display cover plate cover. Rotate screw ("Low LBs") in small
increments until the displayed tension matches the tension indicated on the calibrator. Set
the machine tension to 60 lbs. and apply tension to the calibrator. If the measured tension
is innacurate, rotate screw ("High LBs") in small increments until the displayed tension
matches the tension indicated on the calibrator. Since adjustment of the "Low LBs" screw
at 20 lbs can influence the tension at 60 lbs and visa versa, repeat these steps until the set
tension matchs the tension reading of the calibrator at both 20 and 60 lbs. Replace the
rectangular cover in the L.E.D. display cover plate.
Please note that there will be a range of tension from the maximum tension at which the
tensioner stops pulling (high end of the range), to the minimum tension at which the tensioner
starts pulling again (low end of the range). This difference between the high and low end of
the range can vary from 2-4 lbs depending on the string used to calibrate the machine and
the speed of the tensioner. For consistency, we recommend that the tension setting of the
machine be calibrated as close as possible to the high end of the range, using the fast pulling
speed and a synthetic string, which is the method used at the factory. Using this method will
be the most consistent and will also insure that the racquet will not be over tensioned.
Tension Calibration Procedure
If you suspect that your Progression ESII+ is not
pulling the correct tension, you should check the
tension with a Tension Calibrator which provides
Low KGs
a measurement of the actual pulling tension
being applied by the machine.
With the machine set for the fast pulling speed,
and the tension set at 20 lbs., place one end of
Units
a calibrator equipped with synthetic string into a
Selection
Switch
string clamp. Place the opposite end into the
string gripper and apply tension. If the measured
tension is inaccurate, remove the rectangular
12