3. Connect the controller to the Ventilation Kit
Electrical connecting diagram for the back of the Wall Mounted Controller
• 240V supply attaches to position 1 (Neutral), and 2 (Live).
• The cabling to the Fan attaches to 5 (Neutral) and 6 (Live).
• The Thermostat wiring for the Heater attaches to S1, positions 9 and 10.
• Additional thermostat for S2 (11, and 12) not supplied. The flue damper option (7
&8) isn't available for Australia Standards.
• Ensure the thermostat is fixed below the heater as per instructions. See 7 below.
• The Earth Wiring from the controller must be joined to the Earth from the Fan and
the Earth from the 240V supply. Use the blue Connector to join the 3 Earths
together.
• Note the fan comes with the heat resistant silicon cables that must be used for
wiring through the heater enclosure area.
The cabling and plug for the 240V mains supply to the controller: The 3 pin plug is
not connected, if a longer cable is required or the unit will be hardwired, please
discuss this with your electrician.