Major tech MT760 Manual - Página 2
Procurar online ou descarregar pdf Manual para Instrumentos de medição Major tech MT760. Major tech MT760 4 páginas. 100a ac/dc trms mini clamp meter
Também para Major tech MT760: Manual de instruções (16 páginas)
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to
the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous
voltages may be present
Double insulation
SAFETY NOTES
•
Do not exceed the maximum allowable input range of any function
•
Do not apply voltage to meter when resistance function is selected.
•
Set the function switch OFF when the meter is not in use.
WARNINGS
•
Set function switch to the appropriate position before measuring.
•
When measuring volts do not switch to current/resistance modes.
•
When changing ranges using the selector switch always disconnect the test leads from the
circuit under test.
•
Do not exceed the maximum rated input limits.
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for any damage before operating the
meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Remove the battery if the meter is to be stored for long periods.
Always discharge capacitors and remove power from the device under test before performing
Diode, Resistance or Continuity tests.
• Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
• If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Function
A AC, VDC
V DC, V AC
Resistance, Continuity Test
Input Limits
Maximum Input
200A (PEAK 282.8A)
600V DC/AC
600V DC/AC
1
Meter Description
1. Current clamp & Non-contact AC voltage detector probe tip
2. F lashlight
3. Non-contact AC voltage(NCV) indicator light
4. F lashlight on/off button
5. Rotary Function swith
6. Clamp trigger
7. LCD display
8. Select Peek hold, MAX/MIN Hold, DCA Zero,DC/ACV function button
Peak Hold function (only ACA range)
DCA Zero (only DCA range)
MAX/MIN Hold function (Use to DCA,DCV,ACV, Resistance range )
DC/ACV (select DC Vor ACV )
9. Data Hold & Backlight button
10. COM input jack
11. V
jack
12. Battery Cover
2