2. Turn the rotary switch to the
3. Press the MODE button until "
4. Touch the test probes to the diode under test. Forward voltage will
indicate 0.4V to 0.7V. Reverse voltage will indicate "OL". Shorted devices
will indicate near 0mV and an open device will indicate "OL" in both
polarities.

4.5. Data Hold

To freeze the LCD meter reading, press the data hold button. The data hold
button is located on the left side of the meter (top button). While data hold
is active, the DH display icon appears on the LCD. Press the data hold
button again to return to normal operation.
4.6. MAX Hold
To hold the highest reading on the LCD, press the MAX hold button. The
MAX hold button is located on the left side of the meter (bottom button).
The meter reading will not change as readings change, rather it will only
display the highest reading encountered since the MAX hold button was
pressed. Press the MAX hold button again to return to normal operation.

4.7. Manual Ranging

The meter turns on in the autoranging mode. Press the Range button to
go to manual ranging. Each press of the range button will step to the next
range as indicated by the units and decimal point location. Press and hold
the Range button for two seconds to return to autoranging. Manual
ranging does not function in the AC Current, Diode and Continuity check
functions.

4.8. Backlight

The backlight function illuminates the display and is used when the ambient
light to too low to permit viewing of the displayed readings. Press the
button for one second to turn the backlight on and press the button a
second time to turn the backlight off.

4.9.Battery Replacement

1. Remove the one rear Phillips head screw
2. Open the battery compartment
3. Replace the Requires two "AAA" batteries (UM4 R03)
4. Re-assemble the meter
position.
" appears in the display.