INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Undercounter
Installation
(with cooktop
installed above):
Ovens approved for this type of installation have an approval
label located on the top of the oven. Refer to undercounter
installation instructions for cutout dimensions and approved oven
cooktop combinations
(separate sheet).
Tools needed
•
Phillips screwdriver
•
Measuring tape
•
Drill (for wall cabinet installations)
•
1" (25 mm) drill bit (for wall cabinet installations)
•
Level
Parts needed
•
UL listed or CSA approved conduit connector
•
UL listed wire connectors
Parts supplied
•
2 - #8-14 x 1" screws
•
Bottom vent (supplied on some models)
•
2 - #8-18 x 3/8"screws - bottom vent (supplied on some
models)
Check local codes. Check existing electrical supply. See
"Electrical Requirements."
It is recommended
that all electrical connections
be made by a
licensed, qualified electrical installer.
IMPORTANT:
Observe all governing codes and ordinances.
•
Cabinet opening dimensions that are shown must be used.
Given dimensions
provide minimum clearance with oven.
•
Recessed installation area must provide complete enclosure
around the recessed portion of the oven.
•
Grounded electrical supply is required. See "Electrical
Requirements"
section.
•
Electrical supply junction box should be located 3" (7.6 cm)
maximum below the support surface when the oven is
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter
hole should be located in the right rear or left rear corner of
the support surface to pass the appliance cable through to
the junction box.
NOTE: For undercounter
installation, it is recommended
that
the junction box be located in the adjacent right or left
cabinet. If you are installing the junction box on rear wall
behind oven, the junction box must be recessed and located
in the upper or lower right or left corner of the cabinet;
otherwise, the oven will not fit into the cabinet opening.
•
Oven support surface must be solid, level and flush with
bottom of cabinet cutout. Floor must be able to support a
single oven weight of 140 Ibs (63.5 kg).
Product Dimensions
E
B
A. 28¼" (71.8 cm) max. recessed width
B. 28_"
(72. 7 cm) overall height
C. 293/4" (75.6 cm) overall width
D. 23_"
(58.4 cm) max. recessed depth
E. 2T/2" (69.9 cm) recessed height
Cabinet Dimensions
Oven Undercounter (without cooktop installed above)
E
i
B
C
A. 30" (76.2 cm) min. cabinet width
B. 11/_ '' (3.8 cm) min. top of cutout to
underside of countertop
C. 51/4'' (13.3 cm) bottom of cutout to floor
D. 287/2'' (72.4 cm) cutout width
E. 273/4'' (70.5 cm) min. cutout height
2