MAJORCHARGE MajorCharge24/25 Manual do Proprietário - Página 7
Procurar online ou descarregar pdf Manual do Proprietário para Carregador de bateria MAJORCHARGE MajorCharge24/25. MAJORCHARGE MajorCharge24/25 8 páginas. Gel, pro, hd series 6/8/12/16/24/36/48 volt
YELLOW CHARGE LIGHT DOES NOT SWITCH ON:
The charger will not commence charging unless
properly connected.
1. Check to ensure the charger is connected
correctly. – BLACK lead to NEGATIVE (-)
terminal and RED lead to POSITIVE (+) terminal
or that the factory-installed OEM (Original
Equipment Manufacturer) custom connector is
properly installed regarding the polarity at the
connectors contact terminals or at the mating
connector on the battery or equipment.
2. Check that the clips made a good connection to
the battery posts. Twist clips or clean battery
posts to ensure good connection
GREEN READY LIGHT DOES NOT APPEAR AFTER 18
HOURS:
3. The Microprocessor Control can indicate a
problem with the battery. If the battery has not
reached the First Stage of the Operation within 18
hours, the charger may determine that a problem
exists within the battery or the battery is too big for
the charger's output rating. The OVERRIDE
TIMER FUNCTION is indicated by the GREEN
LED FLASHING.
1. Two 6 Volt batteries may be charged with the
charger if they are connected in series as shown
in Figure 2.1.
CAUTION: NEVER UNDER ANY CIRCUMSTANCES
ATTEMPT TO CHARGE A SINGLE 6 VOLT
BATTERY WITH THIS CHARGER. THIS WILL
RESULT IN SERIOUS DAMAGE TO THE BATTERY
AND CREATE A RISK OF EXPLOSION. EXTREME
CARE SHOULD BE TAKEN TO CONNECT THE
BATTERIES ONLY AS SHOWN ABOVE.
IMPROPER CONNECTION CAN RESULT IN
EXPLOSION AND SERIOUS INJURY.
MajorPower.Com
2. Two or more 12 Volt batteries may be bank
charged with the (1) charger if they are connected
in parallel as shown in Figure 2.2.
NOTE: It is important that the batteries in the circuit be
of the same type (e.g. maintenance-free only or
conventional lead-acid only). Mixing different types of
batteries in the same circuit will result in improper
charging.
1. Two 12 Volt batteries may be charged with a 24
Volt charger if they are connected in series as
shown in Figure 2.1.
CAUTION: EXTREME CARE SHOULD BE TAKEN
TO CONNECT THE BATTERIES ONLY AS SHOWN.
IMPROPER CONNECTION CAN RESULT IN
EXPLOSION AND SERIOUS INJURY.
1. When not in use, store the charger in a cool, dry
place, preferable in its original packaging.
2. Place these instructions with the charger.
Very little maintenance is required other than
protecting it from damage and weather.
1. Coil cord when not in use.
2. Clean case and cords with a slightly damp cloth.
3. Corrosion on the clips may be removed with a
solution of water and baking soda.
4. Examine cords for damage periodically. Replace if
necessary with manufacturer approved parts.
This charger is a solid-state device and should not
require service under normal operating conditions and
if used according to these instructions. For service,
call or write the manufacturer.
CAUTION: RISK OF ELECTRICAL SHOCK.
Do not attempt any servicing unless you are
authorized and qualified to do so.
http://www.majorpower.com