IKEA ID3CHEXWQ00 Instruções para o utilizador - Página 12
Procurar online ou descarregar pdf Instruções para o utilizador para Frigorífico IKEA ID3CHEXWQ00. IKEA ID3CHEXWQ00 33 páginas. Whirlpool
Base Grille Water Filtration System
Model TIWG2L/T2RFWG2
Capacity
200 Gallons (757 Liters)
Model TIWG2/T2RFWG2
Capacity
200 Gallons
(757 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I1"; and against
NSF/ANSI
Standard
53 for the reduction
of Mercury,
Benzene,
Toxaphene,
O-dichlorobenzene,
and Carbofuran.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I1"
Contaminant
Reduction
Lead: @ pH 6.5***
Lead: @ pH 8.5***
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Carbofuran
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.6 mg/L
0.003 mg/L
0.04 mg/L
Average
Influent Challenge
Maximum
Average
Minimum %
Influent
Concentration
Effluent
Effluent
Reduction
2.0182 mg/L
2.0 mg/L + 10%
0.06 mg/L **
0.0536 mg/L
97.03
1333333 #/mL
At east 10,000 part c es/mL
6600 #/mL
2325 #/mL
99.51
Average
Influent
0.1533 mg/L
0.1400 mg/L
0.0058 mg/L
0.0059 mg/L
0.0154 mg/L
1.7571 mg/L
0.015 mg/L
0.0819 mg/L
Influent Challenge
Concentration
0.15 mg/L_+ 10%
0.15 mg/L_+ 10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.015 mg/L _+10%
1.8 mg/L _+10%
0.015 mg/L _+10%
0.08 mg/L _+10%
Maximum
Effluent
0.0005 mg/L
0.0007 mg/L
0.0002 mg/L
0.0005 mg/L
0.0012 mg/L
0.0250 mg/L
0.001 mg/L
0.0400 mg/L
Average
Effluent
0.0005 mg/L
0.0006 mg/L
0.0002 mg/L
0.0003 mg/L
0.0006 mg/L
0.0066 mg/L
0.001 mg/L
0.0213 mg/L
Minimum %
Reduction
99.67
99.50
96.54
91.57
92.22
98.58
93.33
51.13
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (2O°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
•
It is essential
that operational,
maintenance,
and filter
•
replacement
requirements
be carried
out for the product
to
perform
as advertised.
•
Use replacement
filter T2RFWG2,
part #4396841.
2008 suggested
retail price of $39.99
U.S.A./S54.95
Canada.
Prices are subject
to change without
notice.
Model TlWG2L:
Style
1 - When the filter indicator
reads 10%,
order a new filter. When the indicator
reads 0%, it is
recommended
that you replace the filter.
Style 2 - When the filter indicator
changes
from green to yellow,
order a new filter. When the indicator
changes
from yellow to red,
it is recommended
that you replace the filter.
Style 3 - When the water filter status display changes
from
"GOOD"
to "ORDER,"
order a new filter. When the filter indicator
reads "REPLACE,"
it is recommended
that you replace the filter.
Style 4 - Press FILTER to check the status of your water filter. If
the filter indicator
light is yellow, order a new filter. If the filter
indicator
light is red, it is recommended
that you replace the filter.
Model TlWG2:
Change the water filter cartridge
every 6 months.
If the water flow to the water dispenser
or ice maker decreases
noticeably
before 6 months
have passed,
replace the water filter
cartridge
more often.
Average %
Reduction
97.34
99.83
Average %
Reduction
99.67
99.57
96.54
94.92
96.34
99.63
93.33
74.00
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
•
The product
is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown
quality
without
adequate
disinfection
before or after the
system.
•
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
•
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm
(1.9 Lpm) @ 60 psi
*Class II particle size: 1 um to <5 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
***Compliant
for Lead reduction requirements
under NSF/ANSl Standard 53 as tested by Pace Analytical Services, Inc.
® NSF is a registered trademark
of NSF International.
12