The ice cubes are hollow or small
This is an indication of low water pressure.
Check the following:
Is the water shutoff valve fully open?
Are there kinks in the water lines that could restrict water
flow?
If you are using a water filter, remove the filter and operate the
dispenser. If water flow increases, the filter is clogged or
incorrectly installed.
Is a reverse osmosis water filtration system connected to
your cold water supply? See "Water Supply Requirements"
in either the Installation Instructions or the Use & Care Guide.
If you still have questions regarding your water pressure, call a
licensed, qualified plumber.
Off-taste,
odor or gray color in the ice
Check the following:
Are the plumbing connections
new, causing discolored or off-
flavored ice?
Have the ice cubes been stored too long?
Does the freezer and ice bin need to be cleaned?
Has food in the freezer or refrigerator been wrapped properly?
Does the water contain minerals (such as sulfur)? A filter
may need to be installed to remove the minerals.
Is there a water filter installed on the refrigerator? Gray or
dark discoloration
in ice indicates that the water filtration
system needs additional flushing.
The ice dispenser will not operate
properly
Check the following:
Is the freezer door closed completely?
Is the ice bin installed correctly?
Is there ice in the bin?
Has the ice frozen in the ice bin?
Is ice stuck in the delivery chute?
Has the wrong ice been added to the bin? Use only cubes
produced by the current ice maker.
Has the ice melted around the auger (metal spiral} in the
ice bin? Dump the ice cubes and clean the ice bin.
Is the ice dispenser stalling while dispensing "crushed"
ice? Change the ice button from "crushed" to "cubed." If
cubed ice dispenses correctly, depress the button for
"crushed" ice and begin dispensing again.
Has the dispenser arm been held in too long? Ice will stop
dispensing when the arm is held in too long. Wait 3 minutes
for dispenser motor to reset before using again.
The water dispenser
will not operate
properly
Check the following:
Is the freezer door closed completely?
Is the water shutoff valve not turned on, incorrectly installed or
clogged?
Is the water line connected at the source?
Is there a kink in the home water source line?
Has the water system not filled? The water system needs to
be filled the first time it is used.
Is the refrigerator connected to a cold water line with
water pressure of at least 30 psi? The water pressure to the
home determines the flow from the dispenser.
Is there a water filter installed on the refrigerator? The filter
may be clogged or incorrectly installed.
Is a reverse osmosis
water filtration
system connected
to
your cold water supply?
See "Water Supply Requirements"
in either the Installation Instructions or the Use & Care Guide.
Water is leaking from the dispenser
Check the following:
Is the glass not being held under the dispenser long enough?
Has the water system been flushed since installation or
changing filters?
The dispenser
water is not cool enough
NOTE: Water from the dispenser is only chilled to 50°F (10°C).
Has the refrigerator
been newly installed
or a large
amount of water recently dispensed?
Allow 24 hours for the
refrigerator to cool completely.
Has water not been recently dispensed?
The first glass of
water may not be cool. Discard the first glass of water.
WATERFILTER
CERTIFICATIONS
Stale of California
Del)ar{ment of Health Services
Water
Treatment
Device
Certificate
Number
03-
1550
Dal_ Issll_'d: Jai/uary 21, 2003
Tradomark/Modol
Designali0n
Replacement
Elements
Rated Caaa_
WhMpool
Wk-NL2_
NL24£
240 gal
_Ju gal
_anufacturer
_"
t_ol Corn
_e water
treatmeat
dewce
s I s_ed on this certificate
have met the test ng reqmremen_s
pursuant
to Section
116830
of the Health
aRd Salary
Code
lhr the _llov*in_
llcalth
rela_ed
contaminants:
Microbiological
Contaminants
and
Ta rbiditx
I n o r _ani_iRadiolo_i¢
al Contaminants
Non_
N_n_
Organic
Cent
arainanls
1ca_l
Rated
Seryice
Flow:
)5 _pm
Do hilt use with water
that is mierobiologieallT
unsafe
or of unknown
quality_
without
adequate
disinfection
before
or after
the system.
10