Decofire DF102043 Instruções de montagem, segurança e funcionamento - Página 14

Procurar online ou descarregar pdf Instruções de montagem, segurança e funcionamento para Aquecedor Decofire DF102043. Decofire DF102043 17 páginas. Rapid reduction area heater
Também para Decofire DF102043: Instruções de montagem, segurança e funcionamento (17 páginas)

Decofire DF102043 Instruções de montagem, segurança e funcionamento

CARE AND CLEANING

• Never clean this appliance when it is hot - always allow
the appliance to cool completely before cleaning or
maintenance.
• Before performing any maintenance always shut off all gas
controls and valves and disconnect the gas cylinder from
the appliance.
• Do not use high pressure water blasting devices to clean
the surfaces of the appliance body as this may damage or
remove the surface coatings.
• Always check any cleaning product on a small area of
the underside of the product to confirm it is safe to
use. Note: Permanent damage may occur if powder or
solvent cleaners come in contact with painted or plastic
components on this appliance.
• Avoid using harsh chemical cleaners, sprays or highly
abrasive cleaning tools.
• Harsh weather conditions may cause stubborn stains,
discoloration and possibly rust pitting.
• Carbon deposits may pose as a fire hazard; clean the
reflector and inside of the glass tube with soap and water
if any carbon deposits are present.
Care: Body - Painted Finishes
Wipe the appliance over with a soft damp cloth and mild
detergent if required. Rinse with clean water and dry off all
components with a soft cloth before using appliance.
Care: Glass Components
Regularly clean the glass tube with a glass cleaner and rinse
with clean water and then dry the glass with a soft cloth.
Ensure the glass tube is completely dry before reinstalling
into the appliance.
Care: Stainless Steel / Aluminium Components
Regularly clean the visible stainless steel or aluminium
components with a suitable approved cleaner. Follow the
manufacturers instructions for cleaning and then rinse the
components with clean water and then dry the components
with a soft cloth. Ensure all components are completely dry
before using the appliance.
STORAGE
When not in use, this appliance must be protected from
exposure to the elements: e.g. Sun, Wind, Rain, Dust, Snow
and Ice.
Cover this appliance at all times when not in use or move
this appliance to a covered outdoor space or store the
appliance in a dry environment, for example, a garage or
suitable storage space.
If this appliance is being stored indoors, the gas cylinder
must be turned off at the cylinder valve and the gas cylinder
must be disconnected from the appliance. It is generally
recommended that any gas cylinder - when not in use - be
stored outdoors in a secure, protected and well ventilated
area.
Page 14
CLEANING, MAINTENANCE
& SERVICING SCHEDULE
Service Item
Major appliance
inspection and service
This appliance should be
inspected and serviced
by a qualified gas service
technician.
Cleaning: Appliance Body,
Glass Flame Tube, Mesh / Wire
Guard, Burner, Reflector.
Gas leak test.
Inspect burner and flame
control operation.
Check ignition / starter
system and battery.
Inspect hose and regulator
for damage, abrasion, cuts or
other damage.
Inspect the POL connector
and 'O' Ring.
Inspect the glass flame tube
for damge or cracks.
Inspect appliance guard for
damage - ensure guard is
secured to appliance.
Inspect gas cylinder. Check
for corrosion or damage to
cylinder and valve.
Check valve operation.

SPARE PARTS

Where components require replacement these should be
obtained from the original supplier - or as advised by your
gas service technician.
Using non manufacturer approved parts or accessories may
result in a defective condition and void the warranty of this
appliance.
Recommended
Interval
2 years
6 months or, more
frequently if required.
1-2 months or,
Whenever gas cylinder is
refilled or,
If the hose and regulator
has been disconnected.
12 months.
12 months.
6 months or, whenever
the cylinder is refilled.
12 months or, whenever
the cylinder is refilled.
6 months.
6 months.
6 months or,
Whenever cylinder is
refilled or reconnected
to the appliance.