decoflame Atlantic Series Manual do utilizador - Página 12
Procurar online ou descarregar pdf Manual do utilizador para Lareira de interior decoflame Atlantic Series. decoflame Atlantic Series 17 páginas. Wall-mounted decoflame bioethanol fireplace
decoflame® Atlantic Series User Manual English – Version 3 – January 2013
Concrete / Brick walls
Use stainless steel expansion bolts. Their anchor must reach at least 50mm into the concrete or
brick wall (excluding any plaster). Each bolt must be able to bear 50 kg.
50mm
Wooden walls
The screws have to penetrate the wooden construction by least 45mm. Each screw must be
able to bear 50 kg.
45mm
IMPORTANT: Use
12
ONLY
metal fixing devices.
concrete / bricks
plaster
mounting bracket
wooden wall
mounting bracket