KitchenAid KECX100 Manual de instruções de instalação - Página 6
Procurar online ou descarregar pdf Manual de instruções de instalação para Placa de fogão KitchenAid KECX100. KitchenAid KECX100 6 páginas. Electric built-in cooktops
SECTION
E -
REPLACEMENT
INSTALLATIONS
THE FOLLOWING
INSTRUCTIONS
ARE FOR REPLACEMENT
INSTALLATIONS
ONLY.
Before installing
unit be sure that the electrical
supply meets the electrical
specifications
given in this booklet
for your particular
model.
ELECTRICAL
SUPPLY
A 4-foot length of flexible conduit is provided with each cooktop for connection to the junction box. All burner boxes
are 3 inches deep. An additional
4 inches at the rear of the burner box is needed for the electrical connections.
See side view of Figure 1.
CABINET CONSTRUCTION
All surface units are designed for installation
in a base cabinet with a countertop depth of 24 inches. For informa-
tion on top cabinet location see notes below.
The minimum and maximum countertop
cutout dimensions
are given in Figure 4 and chart below according
to
model number. The side and rear wall clearances
in the diagram are recommended
clearances.
IMPORTANT NOTE: In order to comply with.UL safety standards the front edge of the cooktop must be a minimum of
V/z inches from the front edge of the countertop (See Figure 5) and the sides of the cooktop must be a minimum of
1 inch away from any vertical sidewalls.
TOP CABINET
NOTE:
To
eliminate
the
risk of burns or fire by reaching over
the
heated surface units, cabinet storage space located above the
surface unit should be avoided.
If cabinet storage is to be pro-
vided, the risk can be reduced by installing
a range hood that
projects horizontally
a minimum of 5 inches beyond the bottom
of the cabinets.
NOTE:
"A"
= 30" min. clearance
between the top of the cook-
ing surface and the bottom of an unprotected
wood or metal
cabinet.
"A"
= 24" min. when bottom of wood or metal cabinet is pro-
tected by not less than l/q" flame retardant millboard covered with
not less than No. 26 MSG sheet steel, 0.024" aluminum, 0.015"
stainless steel or 0.020" copper.
COUNTERTOP
CABINET
CUTOUT
DIMENSIONS
FOR
REPI ACEMENT
INSTALLATION
INFORMATION
30" MODELS
36" MODELS
Minimum
Maximum
Minimum
Maximum
Width
26% If
295/s"
33"
347/s"
Depth
16'/4"
205/s"
16%"
205/81
Fgule 4
UNPACK UNIT
Remove all packing material from unit and any accessories.
Grill/Griddle
Models - Assemble grill/griddle
as shown in Figure 3. Set aside.
Remove both front electric elements by raising element slightly and pulling directly away from receptacle. Remove
the front two drip bowls. Set aside.
When raising or lowering the cooktop itself use the front two element openings.
CONTINUE
INSTALLATION
INSTRUCTIONS
WITH SECTION
D -
INSTALLING
UNIT
307749
-6-