KitchenAid KFGS306VSS02 Manual de instruções de instalação - Página 2
Procurar online ou descarregar pdf Manual de instruções de instalação para Placa de fogão KitchenAid KFGS306VSS02. KitchenAid KFGS306VSS02 20 páginas. 30" (76.2 cm) and 36" (91.4 cm) gas built-in cooktop
Também para KitchenAid KFGS306VSS02: Lista de peças (5 páginas)
I
WARNING:
If the information
in this manual is not followed
exactly,
a fire or explosion
I
I
may result causing
property
damage,
personal
injury or death,
I
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity
of this
or any other appliance,
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation
and service
must be performed
by a qualified
installer,
service agency
or
the gas supplier.
In the State of Massachusetts,
the following installation instructions apply:
• Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
• If using a ball valve, it shall be a T-handle type.
• A flexible gas connector, when used, must not exceed 3 feet.
INSTALLATION REQUIREMENTS
oosc_d
Pods
Gather the required tools and parts before starting installation.
Tools needed
•
Tape measure
•
•
Flat-blade screwdriver
•
•
%2" (#0 [2 mm]) flat blade
•
screwdriver (screwdriver
shaft must be a minimum of •
11/8"[28 mm] long)
•
15/16" c ombination
wrench
•
•
Pipe wrench
Wrench or pliers
Needle-nose pliers
Marker or pencil
Pipe-joint compound
resistant to LP gas
Noncorrosive leak-detection
solution
Parts supplied
•
Gas pressure regulator
•
Burner grates
•
Burner caps
•
Clamping brackets (2)
•
21/2 '' (6.4 cm) clamping screws (2)
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See "Electrical Requirements"
and
"Gas Supply Requirements"
sections.
IMPORTANT: Observe all governing codes and ordinances.
Do
not obstruct flow of combustion
and ventilation ain
•
It is the installer's responsibility
to comply with installation
clearances specified on the model/serial rating plate. The
model/serial
rating plate is located on the underside of the
cooktop base.
=o
° °
A
/
A, Model/serial rating plate
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.