1.8 Functions
The following functions of the unit can be set using the control element:
•
Automatic Operation
•
Manual Operation
•
Ventilation Stage 1-3
•
Basic Ventilation
•
Off
Automatic Operation (Only possible with optional sensors)
When the A button is pressed, automatic operation of the unit is activated and displayed by the lit-up LED
next to the A button. The ventilation stages are automatically controlled based on the air quality.
The ventilation stages LEDs display the selected ventilation level setting (level 1, level 2, level 3). This can
be manipulated by pressing the up and down arrow buttons. After a short time of inactivity, the LEDs are
turned off. Display them again by briefly pressing the arrow buttons.
Manual Operation
Manual operation is activated by pressing the M button and displayed by the LED next to the button. The
ventilation unit is in manual operation now. The individual ventilation levels can be changed and set with the
arrow buttons on the right of the LEDs. The LEDs display the selected ventilation level. If ventilation level 1 is
flashing, basic ventilation is selected. If the down button is pressed until none of the three LEDs are lit up or
flashing, the unit is deactivated (only possible when basic ventilation is deactivated).
Basic ventilation
If ventilation level 1 is flashing, basic ventilation is active. Basic ventilation ensures a minimum air flow which
serves as moisture protection.
OFF (only possible when basic ventilation is deactivated)
When "Off" mode is selected, the unit's dampers will be closed and the air discharge/supply to the service
unit will be interrupted.
Error Message
The error message shall be displayed in case of a unit operating error by lighting up the LED. If an error
message is displayed, promptly inform the relevant persons or seek advice from your point of sale contact.
4