Gantner GAT NET.Lock 7000 Manual - Página 3

Procurar online ou descarregar pdf Manual para Mobiliário de interior Gantner GAT NET.Lock 7000. Gantner GAT NET.Lock 7000 6 páginas. Electronic locker locks

Mounting and Installation Instructions

The GAT NET.Lock 7000 is mounted with 3 screws (1) on the inside of the
locker. The bolt set with the door shackle is mounted on the inside of the
locker door. At non-metallic doors only a drilling for the LED is required. At
metallic doors a cut-out must be made in the door, where the bolt set and
label carrier will be mounted.
Door status contact
The GAT NET.Lock 7000 has a contact which gets activated by the door
contact (5) at the bolt set as soon as the locker door is closed. This allows
to determine the open/close state of the door. To guarantee the correct
functionality of the GAT NET.Lock 7000 it is important that this contact is
clean and not damaged.
Mounting on Non-Metallic Doors
3
6
2
4
7
5
6
17.0 mm
17.0 - 17.5 mm
8.0 mm
Installation measures for GAT NET.Lock 7000 and Bolt Set
During the mounting, please pay particular attention to the following points:
- When the door is pressed shut, the gap between the bolt set (2) and the
front of the GAT NET.Lock 7000 must not be exceed 0.5 mm. Ideally the
bolt set should touch the front of the lock.
- The middle of the door shackle (4) must be 1 mm higher than the middle
of the door shackle opening in the GAT NET.Lock 7000. This ensures
the door's ability to close even if the door position is modified 3 mm
downwards or 1 mm upwards (tolerance ±2 mm).
Mounting procedure
Note: Before mounting all locks of the locker system a test installation of
at least one lock and final function check must be performed like
described below. Only if the tests are successful the rest of the
locks may be mounted in the same way.
1. Drill the three holes (3) for the GAT NET.Lock 7000 into the locker
wall.
2. Plug-in the connection cable (see page 6).
www.gantner.com
1
3
3
74.0 mm
Door width
The minimum allowed door width (measured from the door shackle to the
hinge) is 230 mm. If the door is narrower than this measure, the door
shackle would hit the locker when the door is being closed.
1
6
3
2
3
7
3
6
2.4 mm
10.1 mm
14.6 mm
17.6 mm
25.1 mm
3. Mount the GAT NET.Lock 7000 with three screws (3) on the inside
locker wall.
Note: Use the right screws according to the type of locker material.
Attention: The max. allowed tightening torque of the screws
is 2 Nm.
4. Drill the three holes (6) for mounting the GAT NET.Lock Bolt Set 7100.
5. Drill a hole for the LED display in the locker door (7). The recommended
hole diameter is 10 mm.
Note: A front label can be used to cover the LED hole. If the customer
designs the label he must pay attention that a transparent field for the
LED light should be placed on the label.
6. Mount the bolt set onto the locker door by using three screws.
Note: Use the right type and length of the screws according to the
type of locker material.
Attention: The max. allowed tightening torque of the screws
is 2 Nm.
7.
Close the locker door to test, if the door can be closed easily and the
door shackle inserts into the opening in the GAT NET.Lock 7000.
Valid as from September 27
2013 • Technical data subject to modifications without notice!
th
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
Centre of rotation of hinge
Locker door
min. 230 mm
1. GAT NET.Lock 7000
2. GAT NET.Lock Bolt Set 7100
3. Mounting screws for GAT NET.Lock 7000
4. Door shackle
5. Door contact
6. Mounting screws for bolt set
7. LED (hole in locker door)
3