IKEA MATMASSIG Manual - Página 15

Procurar online ou descarregar pdf Manual para Hob IKEA MATMASSIG. IKEA MATMASSIG 44 páginas.
Também para IKEA MATMASSIG: Manual (28 páginas), Manual (24 páginas), Manual (44 páginas), Manual (28 páginas), Manual (48 páginas), Manual (36 páginas), Manual (28 páginas), Manual (44 páginas), Manual (29 páginas), Manual (12 páginas), Manual (48 páginas)

IKEA MATMASSIG Manual
ENGLISH

Electrical connection

Warning! Refer to Safety
chapters.
Warning! All electrical
connections must be made by an
authorised installer.
Electrical connection
• Before connecting, check if the nominal
voltage of the appliance, provided on
the rating plate, corresponds to the
available supply voltage. The rating
plate is located on the lower casing of
the hob.
• Follow the connection diagram (it is
located on the underneath surface of the
casing of the hob).
• Use only original spare parts provided
by spare parts service.
• The appliance is not provided with a
mains cable. Buy the right one from
Connection diagram hob
One-phase connection 220 V - 240 V ~
1
2
3
N
Insert the bridge between the
screws as shown.
Main power connection 1-phase
• You must have the means for
• You must have the connection and the
• The earth lead is connected to terminal
• Secure the connecting cable with cable
Two-phase connection 400 V 2L-1N ~
L
N
PE
Main power connection 2-phase
specialized dealer. Single phase or two-
phase connection requires a mains cable
of minimum 70°C temperature stability.
Cable has been provided with end
sleeves. According to IEC regulations use
for one-phase connection: mains cable 3
x 4mm² and for two-phase connection:
mains cable 4 x 2.5mm². Please respect
specific national regulations in the first
priority.
disconnection incorporated in the fixed
wiring.
connecting links carried out as shown in
the connection diagram.
and must be longer than leads carrying
electric current.
clips or clamps.
1
2
3
N
15
L1
L2
N
PE