ENGLISH

Product description

Control panel

Turns the motor on/off at speed one.
Attention: the product is with the filter alarm disabled.
Press and hold the button for approximately 2 seconds, with all the loads turned off (Motor+Lights), to turn the grease filter alarm on. LED
Speed
(B) flashes twice to confirm.
To turn the alarm off, press the button again and hold for at least 2 seconds. The relevant LED (B) flashes once.
Turns the motor on at speed two / Activate charcoal filter alarm.
Attention: the product is with the filter alarm disabled.
Speed
Press and hold the button for approximately 2 seconds, with all the loads turned off (Motor+Lights), to turn the Activated Charcoal Filter
alarm on. LED (A) flashes twice to confirm.
To turn the alarm off, press the button again and hold for at least 2 seconds.The relevant LED flashes once (A). Only for recirculation mode.
Turns the Motor on at speed three / Reset alarm grease filter saturation.
Press and hold the button for approximately 2 seconds, with all the loads turned off (Motor+Lights), to reset the grease filter
Speed
saturation alarm or charcoal filter alarm. LED (A) flashes three times.
Turns the motor on at Booster speed.
This speed is timed to run for 6 minutes. At the end of this time, the system returns automatically to the speed that was set before. If it is
Speed
activated with the motor turned off, it will switch to OFF at the end of the time. To deactivate it, press button D or press button A.
Press briefly: Turns the lighting system on and off at maximum intensity.
Press and hold to change the lighting intensity up or down.
Light
Filters Alarm.
When the filter alarm is activated, the following messages will appear over time:
Grease filter alarm must be cleaned: "A" key flashes once per second.
Anti-odour filter alarm must be cleaned: "A" key flashes twice per second.
Once the filters have been regenerated reset the alarm signal.
Upper chimney
Lower chimney
Hood body
LED Lighting
Grease filter
Control panel