Note:
Drill the cable hole, when adopting the ceiling outlet
to route the cable.
3. Attach the bracket to the ceiling and secure the
camera with supplied screws.
Figure 2-17 Fix the Camera to the Ceiling
Note:
The supplied screw package contains
self-tapping screws, and expansion bolts.
For cement ceiling, expansion bolts are
required to fix the camera. For wooden ceiling,
self-tapping screws are required.
4. Route the cables through the cable hole, or the side
opening.
5. Connect the corresponding power cord, and video
cable.
6. Power on the camera to check whether the image
on the monitor is gotten from the optimum angle. If
not, adjust the camera according to the figure below
to get an optimum angle.
Rotation Position
[0°to 360°]
1). Loosen the No.3 screw to adjust the pan
position [0° to 360°]. Tighten the screw after
completing the adjustment.
2). Loosen the No.2 screw to adjust the tilt position
[0° to 180°]. Tighten the screw after completing
the adjustment.
3). Loosen the No.1 screw and rotate the camera [0°
to 360°]. Tighten the screw after completing the
adjustment.

3 Menu Description

Purpose:
Call the menu by clicking button
interface, or click Iris+.
Steps:
1. Connect the camera with the TVI DVR, and the
monitor, shown as the figure 3-1.
Figure 2-18 3-axis Adjustment
Pan Position
[0° to 360°]
on the PTZ Control
3
Tilt Position
[0°to 180°]
2
1