Installation (cont.)
Operation
Function Selectors
Temperature Control
IMPORTANT:
The range of the control knob is limited in both clockwise and counter-clockwise directions.
DO NOT force to turn the knob pass its limit. Overturning the control will damage the
thermostatic valve making it fail to regulate temperature.
Water Functions
Overhead Jets
Horizontal Body Jets
Decor Star
8. Once the shower panel has been tested for functions and
leaks. Hang the unit on the wall to complete the installation.
Due to the limited space behind the shower panel, do not
bend the hoses. Any restrictions in the water supply hoses will
greatly reduce the performance of the shower panel. After the
shower panel is set properly on the wall, apply silicon sealant
on both sides of the shower panel to prevent the unit from
moving.
(NOTE: Do not seal the bottom of the panel.)
1. Turn the temperature control knob to set the desired water
temperature. The control is preset to maximum temperature of
100.4 degrees Fahrenheit. To set higher water temperature,
push down the safety pin and turn the dial counterclockwise
to the desired temperature mark. (IMPORTANT: Scalding
may occur if bypass the safety pin, use this control with
caution)
2. Select the desired water function by turning the selector to
the corresponding marking. Multiple functions can be used
simultaneously only if there is adequate water pressure
supplied to the shower panel.
Handheld Shower
Overhead Waterfall
9