Avantco 360BCS35HCW Manual do utilizador - Página 10

Procurar online ou descarregar pdf Manual do utilizador para Frigorífico Avantco 360BCS35HCW. Avantco 360BCS35HCW 10 páginas. Refrigerated bakery display cases

Avantco 360BCS35HCW Manual do utilizador

Troubleshooting

Problem
Compressor not
running .
Condensing units
run for long periods
of time .
Cabinet temperature
is too warm .
Cabinet temperature
is fluctuating .
Condensation is
collecting on the
cabinet and/or floor .
Interior light is not
working .
www.AvantcoRefrigeration.com
10
Possible Cause
Fuse blown or circuit breaker
tripped .
Power cord unplugged .
Thermostat set too high .
Cabinet in defrost cycle .
Excessive amount of warm
product placed in cabinet .
Prolonged door opening or door
ajar .
Dirty condensor coil .
Evaporator coil iced over .
Thermostat set too warm .
Airflow blocked .
Excessive amount of warm
product placed in cabinet .
Fuse blown or circuit breaker
tripped .
Dirty condenser coil .
Evaporator coil iced over .
Low refrigerant levels .
Door is slightly ajar .
Relative humidity is above 55% .
Poor switch connection .
Bulb is not connected .
Bulb is burned out .
User Manual
Refrigerated Bakery Display Cases
Possible Solution
Replace fuse or reset circuit breaker .
Plug in power cord .
Set thermostat to lower temperature .
Wait for defrost cycle to finish .
Allow adequate time for product to cool down .
Ensure doors are closed when not in use . Avoid opening doors
for long periods of time .
Clean the condenser coil . (Page 9)
Unplug unit and allow coil to defrost . Make sure thermostat is not
set too cold . Ensure that door gasket(s) are sealing properly .
Set thermostat to lower temperature .
Re-arrange product to allow for proper air flow . Make sure there
is at least four inches of clearance from evaporator .
Allow adequate time for product to cool down .
Replace fuse or reset circuit breaker .
Clean the condenser coil . (Page 9)
Ensure doors are closed when not in use . Avoid opening doors
for long periods of time .
Contact a service technician to check refrigerant levels .
Make sure door is completely closed .
Move unit to area below relative humidity or lower humidity level .
Turn off light switch and turn it back on .
Make sure the bulb is correctly inserted in the socket .
Replace the bulb .