REINSTATEMENT
M1A - M2A - M3A - M4A - M7A and M10A safety brakes, as safety devices, can stop the
rotation of the shaft to prevent any dangerous acceleration more than once, but each
time they must be reinstated according to the following procedure.
ATTENTION: Each time that the M15A, the M20A and the M30A safety brakes stop,
in order to be reinstated, they must be sent back to GAPOSA srl.
REINSTATEMENT PROCEDURE
(from M1A to M10A models only)
1. Unscrew, according to the sequence in fig. 2, the screws placed on the central body of
the safety brake.
2. Replace the pin projecting out of the central body in its initial position, pushing it in
the opposite direction of the arrow, till the micro switch is set going again; By the M1A
and M2A the hole of the ring must be replaced in the middle of the cavity.
3. Tighten the screws once slightly according to the sequence in fig. 2 and then
complete the screwing up always respecting the sequence by a dynamometrical
key setting it according to Tab. A.

MAINTENANCE

If the installation procedure has been respected, the safety brake does not require any
maintenance.