Avantco 178GDICE49FB Manual de serviço - Página 7
Procurar online ou descarregar pdf Manual de serviço para Merchandiser Avantco 178GDICE49FB. Avantco 178GDICE49FB 18 páginas. Ice merchandisers
Part Testing
Controller Testing
1.
Check for 120 volts between black (L) and white (N)
wires, main power.
2. Check for 120 volts between red (compressor) and
white (L) wires, compressor ON only.
3. Check for 120 volts between gray (defrost) and
white (L) wires, defrost mode only.
4. Check for 120 volts between yellow (fan) and white
(L) wires, fan ON only.
Evaporator Fan Motor Testing
1.
Ensure controller is calling for evaporator fan to run
(Fig. 3) then:
2. Check for 120 volts between yellow (fan) and white
(L) wires, fan ON only. (Fig. 4)
3. Check for 0.3 amps+/- 10% at yellow wire at rear of
controller. (Fig. 4)
4. If tests above fail, replace fan motor.
Condenser Fan Motor Testing
1.
Ensure controller is calling for compressor to run
(Fig. 6) then:
2. Check for 120 volts at fan plug between the blue
and brown wires.
3. Check for 0.4 amps +/- 10% on blue wire.
(Fig. 7)
4. If tests above fail, replace fan motor.
Service Manual
Ice Merchandisers
Fig. 2
Fig. 3
Fig. 4
Fig. 6
www.AvantcoRefrigeration.com
Fig. 5
Fig. 7
7