CORNING ClearCurve SRP-005-065 Manual de início rápido - Página 3

Procurar online ou descarregar pdf Manual de início rápido para Cabos e conectores CORNING ClearCurve SRP-005-065. CORNING ClearCurve SRP-005-065 4 páginas. Drop cable pulling grip kit

Step 3:
Apply the mesh grip as follows:
a) Take a 2-foot piece of the 1/4-inch flame-
retardant mesh grip and press an end
inward so that it expands (Figure 4).
b) Maintain the mesh end expanded and
place the connector in the mesh
(Figure 5).
c) Proceed to inch the mesh up the assembly until 18 inches of the mesh is covering the
assembly end, leaving 6 inches to tie off (Figure 6).
Step 4:
Starting about 1 inch up the cable from the end of the mesh, tape the cable assembly end and
mesh grip using a 1/2 width overlap and keeping a flat lay of the tape. Continue to tape the
cable assembly and mesh grip together until you are about 1 inch into the mesh grip
(Figures 7 and 8).
STANDARD RECOMMENDED PROCEDURE 004-120 | ISSUE 1 | FEBRUARY 2009 | PAGE 3 OF 4
18 in.
End of mesh
1 in.
2 in.
Tape wrap
Figures 4 and 5 — Applying the mesh grip
6 in.
Figure 6 — Grip,placement
Figures 7 and 8 — Taping the mesh grip