5.
MOUNTING RAU5X ONTO BRACKET
Note:
The RAU5x connectors should face the
bracket captive screw.
Referring to Figure 3, perform the following steps:
Step 1:
Insert the four RAU5x pins into the wide
ends of the bracket keyholes.
Step 2:
Make sure that the bracket captive screw fits
into the designated half-slot on the RAU5x.
Step 3:
Lock RAU5x pins into the narrow ends of the
bracket keyholes.
Step 4:
Close captive screw to secure RAU5x and
bracket assembly.
6.
SECURE SAFETY CABLE TO GRID
OR CEILING
IMPORTANT!
Using the supplied security cable, attach the RAU5x to
a permanent structure within the ceiling (e.g., acoustic
ceiling grid or concrete ceiling above).
FIXEZ LE CÂBLE DE SÉCURITÉ À LA
GRILLE OU AU PLAFOND
IMPORTANT!
À l'aide du câble de sécurité fourni, fixez la RAU5x à
une structure permanente avec le plafond (par exemple
plafond acoustique gris ou plafond en béton).
7.
GROUND, F/O, AND RF CABLE
CONNECTIONS
Step 1:
Route the cables located in Section 2.
Step 2:
Connect the earth ground to the RAU5x
8-32 x 3/8 grounding screw (one-hole
grounding lug required). See Figure 4 for
example of RAU5x ground connection.
Step 3:
Connect fiber optic pair to RAU5x module
LC APC optic connector. See Figure 4.
Corning Optical Communications
Figure 3. Mounting RAU5x Onto Bracket
Figure 4. RAU5x Only —GND, F/O, and RF Cable
Connections