73 Series Door Closer Installation
3 8 3 1 1 3
EN1154:1997 + A1:2002 *Fig 1 application only
EN1634-1:2000 FD60 timber FD240 steel
CE 1121-CPD-AD1069 (2007)
Certifire CF600

Standard Door Installation

Pull Side - Fig 1
Washer Screw
Armset Shoe
Hinge Knuckle
Threaded
Arm (bolt)
Adjustment Valves
Dust Cap
Nut
Door Closer Body
Armset
Preload
Armset Pivot Screw

Frame Fix Installation

Washer Screw
Push Side - Fig 61
Armset Shoe
Hinge Knuckle
Threaded
Arm (bolt)
Adjustment Valves
Nut
Door Closer Body
Armset
Preload
Armset Pivot Screw
Step by Step Installation Guide
Use the appropriate template for your installation and place
the template on the door and frame. Pilot drill all fixing holes
as per the template.
1.
Position the door closer with the adjustment valves facing
the hinge side of the door. Secure the door closer using
the screws provided into the pre-drilled pilot positioning
holes.
2.
Attach the armset to the pivot on the door closer body and
secure using the washer screw.
3.
Tension the door closer arm and adjust the arm length
accordingly. Secure the arm set shoe to the door or frame
depending on installation, then tighten the arm set nut.
4.
Apply the dust cap to the unused pivot.
5.
Adjust the closing and latching speeds as required -
refer to adjustment instructions.
NB after the first month of operation the closing and latching
speed valves may require minor adjustment.
Unit 14 Pindar Road, Hoddesdon, Hertfordshire, EN11 0DE
Tel: +44 (0)1992 443 010 | Fax: +44 (0)1992 443 020
Standard Door Installation (Pull Side) - Fig 1
Door Frame
Door
Hinge knuckle
is visable
120 degree
180 degree
door installation
door installation
Dust Cap
Frame Fix Installation (Push Side) - Fig 61
Door Frame
Door
Hinge knuckle
is not visable
120˚ door
180˚ door
installation
installation
2 - Latching Speed
Adjustment Valves
1 - Closing Speed
2 - Latching Speed
2 - Latching Speed
Adjustment Valves
1 - Closing Speed
1 - Closing Speed
To Increase Closing Speed:
Adjust screw valve (1) anti-clockwise by quarter turns until desired speed has been achieved
To Reduce Closing Speed:
Adjust screw valve (1) clockwise by quarter turns until desired speed has been achieved
To Increase Latching Speed:
Adjust screw valve (2) anti-clockwise by quarter turns until desired speed has been achieved
To Reduce Latching Speed:
Adjust screw valve (2) clockwise by quarter turns until desired speed has been achieved
CAUTION
Adjusting valves more than 2 full turns anti-clockwise from factory settings will result in oil leakage damaging the door closer.
Armset Shoe