TECHNICAL SPECIFICATIONS
MAXIMUM OPERATING CONDITIONS
Maximum operating pressure
- Primary circuit: 3 bar
- Secondary circuit: 10 bar
Test pressure
(tank full of water)
- Primary circuit: 4.5 bar
- Secondary circuit: 13 bar
Operating temperature
Maximum temperature: 90 °C
Water quality
• Chlorures: < 150 mg/l (304)
< 2000 mg/l (Duplex)
• 8 ≥ ph ≥ 6
DOMESTIC HOT WATER PERFORMANCES
Peak delivery at 40 °C
Peak delivery at 45 °C
Peak delivery at 60 °C
Peak delivery at 40 °C
Peak delivery at 45 °C
Peak delivery at 60 °C
Continuous delivery at 40 °C
Continuous delivery at 45 °C
Continuous delivery at 60 °C
Start-up time [10-80°C]
Start-up time [15-65°C]
(tank full of water)
E-tech S 160
L/10'
310
L/10'
250
L/10'
168
L/60'
690
L/60'
570
L/60'
375
L/h
413
L/h
354
L/h
248
min
61
min
44
E-tech S 240
E-tech S 290
single phase
532
645
452
548
294
356
880
990
750
845
465
527
413
413
354
354
248
248
93
113
66
81
E-tech S 290
E-tech S 380
tri phase
mono phase
660
855
561
725
365
468
1305
1200
1090
1021
625
636
826
413
708
354
415
248
91
150
65
107
E-tech S 380
tri phase
870
739
472
1516
1270
752
826
708
448
120
86