KitchenAid YKFED500ESS Manual de instruções de instalação - Página 11
Procurar online ou descarregar pdf Manual de instruções de instalação para Gamas KitchenAid YKFED500ESS. KitchenAid YKFED500ESS 16 páginas. 30" (76.2 cm) freestanding electric range with double ovens
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the setscrew on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten the setscrew to the
torque shown in the Bare Wire Torque Specifications chart.
C
D
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
Wire Awg
8 gauge copper
6 gauge aluminum
5. Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link screw. The ground wire
must be attached first and must not contact any other
terminal.
6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
A
B
C
A. 10-32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link screw
7. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
10. Slide range back so rear range foot is under the anti-tip
bracket. See the "Verify Anti-Tip Bracket is Installed and
Engaged" section.
A
B
E
D. Neutral (white) wire
E. Line 2 (red) wire
Torque
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
G
F
D
E
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
3-wire Connection: Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the conduit through the hole and conduit plate on bottom
of range. Allow enough slack to easily attach the wiring to the
terminal block.
A
F
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
2. Attach terminal lugs to line 1 (black), bare (green) ground, and
line 2 (red) wires. Loosen (do not remove) the setscrew on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs.Securely tighten the setscrew to the
torque shown in the Bare Wire Torque Specifications chart.
C
D
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
Wire Awg
8 gauge copper
6 gauge aluminum
B
C
D
E
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
A
B
E
D. Bare (green) ground wire
E. Line 2 (red) wire
Torque
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
11