FOR THE INSTALLER
Leave instruction manual with the homeowner
This firebox complies with ANSI Z21.91 for outdoor use with
Z21.97 burners, 50,000 BTU MAX.
Installation and repair should be done by a qualified service
person. This firebox should be inspected before use and at
least annually by a qualified service person.
During manufacture, this firebox is treated with oils, films
and bonding agents. These are not harmful but may produce
smoke and odor as they burn off during initial operation. This
is normal.
Any modification to this firebox or to controls can be
dangerous. Improper installation or use of the firebox can
cause serious injury or death from fire, burns, explosion or
carbon monoxide poisoning.
The firebox hood must not be modified.
Use Non-Combustible Materials where indicated for the
firebox installation. Non-combustible materials do not ignite.
These include metal, brick, ceramic, concrete, slate, glass,
and plaster. Adhesives must be rated for high temperatures
(300°F +). Any mechanical fasteners used to install material
must also be non-combustible, including wall anchors
and tile spacers. Materials that pass the ASTM E 136 test
(Standard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750C) are considered non-combustible.
When the firebox is installed directly on carpeting, tile or
other combustible material, other than wood flooring, the
firebox must be installed on a metal or wood panel extending
the full width and depth of the enclosure.
Page 4

IMPORTANT SAFETY INFORMATION

FOR THE HOMEOWNER
Alert children and adults to the hazards of high surface
temperatures. Keep children and other at-risk individuals
away to avoid burns or clothing ignition.
Carefully supervise young children when they are in the
same area as the firebox.
Do not hang or place clothing or other flammable materials
on or near the firebox.
Do not allow Combustible Materials adjacent to or in contact
with face of the firebox. Combustible materials include wood,
or other materials that will burn even when treated with fire-
retardant chemicals.
Keep firebox area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
Do not allow fans to blow directly into or at the firebox.
Avoid any drafts that alter burner flame patterns.
Do not operate this firebox with glass doors or weather door
in the closed position. A firebox screen must be in place
when the burner is being used.
Do not use this firebox if any part has been underwater.
Immediately call a qualified service technician to inspect the
firebox and to replace any part of the control system and any
gas control which has been under water.
33857-4-0117