2. Continuous Draining
Water can be automatically emptied by attaching a garden hose to the continuous
drainage port on the back of the dehumidifier. This will allow the unit to run
continuously (depending on the selected humidity level) without having to empty the
water bucket. To drain, simply attach a standard garden hose . The thread standard for
garden hoses in the US and its territories is known as GHT or "garden hose thread"
which has an outer diameter of 1 1/16 inches (1.0625 inches or 27.0 mm) and a pitch
of 11.5 TPI.
• Place dehumidifier on a level surface.
• Unscrew the cap on the back of the unit to access the garden hose nozzle.
• Thread a garden hose (not included) onto the accessible nozzle, lead to a floor drain
and cut to length.
• Make sure that there are no kinks or knots in the garden hose (See picture below).
• Turn on the unit and press the MODE button until set to CONTINUOUS.
8