II Electronic Water Leveler
®
Models K-2100
5.3

Fill Valve Will Not Turn OFF

PCB is bad.
PCB is bad.
Relay is stuck.
|
Installation and Operation Manual
Disconnect the yellow wire
at the controller from the
black wire at the sensor.
Disconnect the yellow/blue wire
at the controller from the
white wire at the sensor.
Twist the yellow wire and the
yellow/blue wire together.
NO
Does the fill
light turn off?
YES
Does valve shut
off in 20 seconds?
NO
Disconnect the blue wires
from the controller.
Measure the voltage across the
blue wires with an AC volt meter.
YES
Does the voltage
measure 24VAC?
NO
Possible Causes
1. Manual lever is on.
2. Diaphram needs cleaning.
3. Diaphram is bad.
4. Valve is bad.
Fill Valve Will Not Turn OFF
YES
Is the fill light on?
YES
Sensor
ENGLISH
NO
is bad.