KitchenAid KGBS 146S Manual de instruções de instalação - Página 3

Procurar online ou descarregar pdf Manual de instruções de instalação para Forno KitchenAid KGBS 146S. KitchenAid KGBS 146S 11 páginas. Gas built-in single & double ovens

-
24'
-
to inside of
back cabinet
ELECTRICAL
2-l/2"
MIN
to upper
cab. doors
MIN
SINGLE OVENS
DOUiiLE OVENS
KGBS 146s
KGBS 246s
-
24" MIN _
I
I
I
- 22-112'MIN
-
i
I
l/2- to lower
cab. doors
-
24-
-
to Inside of
cabinet back
-------
2-112" MIN
to upper
cab. doors _
Floor
,
t
9' MIN
.
1
-
24- MIN -
- 22-112' MIN
Electrical Shock Hazard
l
Electrical ground is required on this appliance.
. Improper connection
of the equipment- grounding conductor line can result in
electrical shock.
l
Check with a qualified electrician if you are in doubt as to whether the appliance
is
properly grounded.
Do Not modify the power supply cord plug. If it will
not
fit
the outlet, have a proper outlet installed by a qualified electrician.
l
Do Not use an extension cord with this appliance.
Such use may result in a fire,
electrical shock or other personal injury.
- Do Not have a fuse in the neutral or ground circuit.
A fuse in the neutral or
ground circuit could result in an electrical shock.
l
This appliance must be connected to a grounded metallic, permanent wiring
system; or a grounding conductor should be connected to the grounding
terminal or
lead on the appliance.
Failure to do so could result in an electrical shock.
Save Installation
Instructions
for the local electrical inspector's use.
A three-wire, 120 volt, 60 Hz, AC only, 15 or20 amp fused electrical
PLUG WITH GROUND PRONG
supply is required. A time-delay
fuse or circuit breaker is recom-
PROPERLY
POLARIZED
AND
mended. It is also recommended
that a separate circuit serving only
GROUNDED
RECEPTACLE
this appliance be provided. A polarized, three-wire,
grounded re-
ceptacle should be installed below the oven and be easily acces-
sible for disconnecting
the power supply cord if oven should ever
need to be serviced. It is the personal responsibility
of the customer
to have a properly grounded, 3-prong wall receptacle installed by a
qualified electrician.
-3