9
INTERRUPT REQUEST LINE
The default interrupt request line is 2 (IRQ2).
The interrupt request line is set with switches 1-4, labeled
IRQ2-IQR5, of switch unit SW2. Interrupt request lines
and their corresponding switch settings are shown in Table
4. Note that only one of the interrupt request line
switches may be closed.
Interrupt
Switch
Request
1
2
3
4
Line
(IRQ2}
(IRQ3}
(IRQ4}
(IRQ~}
·2
1
0
0
0
3
0
1
0
0
4
0
0
1
0
5
0
0
0
1
Table 4.
Interrupt request lines and switch set-
tings. l=ON; O=OFF. The asterisk
(*)
indicates
the default setting.
BOOT PROM AND JUMPERS
The socket labeled Ull is provided for a boot PROM for
applications where the Transporter card will be installed
in a diskless workstation.
Closing jumper EI puts +5 VDC on pin 1 of device UII.
This jumper should be closed only when a PROM device
requiring +5 VDC on pin 1 is used. Jumper El should be
left open otherwise.