Gardena 4000/5 Manual do operador - Página 6

Procurar online ou descarregar pdf Manual do operador para Equipamento para relva e jardim Gardena 4000/5. Gardena 4000/5 11 páginas. Garden pump
Também para Gardena 4000/5: Manual de Instruções (10 páginas), Manual de Instruções (17 páginas), Manual de Instruções (12 páginas), Manual do operador (14 páginas), Manual do operador (10 páginas), Manual de Instruções (18 páginas), Manual do operador (10 páginas), Manual de Instruções (19 páginas), Manual de Instruções (13 páginas), Manual de Instruções (17 páginas)

Gardena 4000/5 Manual do operador
3. For suction head exceeding 4 m secure the suction hose
(e. g. by fastening it to a wooden post).
The pump and the suction hose are relieved from the weight of the
water.
To connect the pressure hose [ Fig. I3 ]:
The pressure hose can be connected either to the delivery side
33.3 mm (G1)-thread of the 120° swivelling connection
of the horizontal connection
(8)
.
1. Screw the tap connector
(7)
onto the pressure outlet
it by hand.
2. Connect the pressure hose with hose connector
connector
(7)
.

3. OPERATION

DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you fill the
pump.
To start the Automatic Home & Garden Pump [ Fig. O1 / O2 ]:
NOTE: The specified maximum self-priming level (see 7. TECHNI-
CAL DATA) is reached only when the pump is full and the pressu-
re hose is held up high directly upstream of the pressure output
during the first self-priming phase. This ensures that the pumped
medium cannot leak from the pressure hose. When using a full
suction hose with a check valve, it is not necessary to hold up the
pressure hose.
1. Unscrew the lid
(9)
of the filter chamber with the spanner
2. Slowly fill in the liquid to be pumped via the filler connection
the overflow (approx. 2 to 3 l) until the water level no longer drops
under the suction side inlet or the water flows out at the horizontal
connector.
3. With fixed installation: Unscrew the cover
flows towards the horizontal connector.
4. Empty any water remaining in the delivery hose so that the air can
escape during filling and priming.
5. Open any shut-off devices in the delivery line (watering accessories,
tap, etc.) so that air can escape before the priming procedure begins.
6. With fixed installation: If the delivery line cannot be emptied due to
fixed installation, unscrew the cover
may escape. Please keep a sufficiently large receptacle at hand for
collection.
(9)
7. Tighten the lid
of the filter chamber up to the stopper
8. Without fixed installation: Lift up the delivery hose just behind the
pressure outlet.
9. Plug the power plug of the connecting cable into a mains socket.
(11)
to position I.
10. Push the on / off switch
The on/off switch lights up and the pump starts.
The suction process can take up to 6 min. If no water is pumped
afterwards, the pump will shut down automatically and display
Error 2 (see 6. TROUBLESHOOTING).
11. Close shut-off devices in the delivery pipeline again when the pump
begins to deliver water continuously.
The pump turns off automatically approx. 10 seconds after closing
the shut-off device.
The pump is ready for operation (Standby).
Electronic control:
The pump features an electronic controller.
If the pressure level falls below the start-up pressure, the pump is started
automatically.
As soon as the water supply is no longer required, the pump is switched
off automatically.
Low quantity programme and leakage warning:
Leakage warning:
In the event of a leakage or a dripping tap, the pressure constantly
falls below the turn-on pressure and the pump switches itself on and
off continuously.
If the pump is constantly switched on and off, the pump switches off auto-
matically to prevent unwanted water leakage (error 4 "Leakage warning" is
displayed).
10
(5)
and / or
(5)
/
(8)
and tighten
(6)
onto the tap
(A)
provided.
(10)
up to
(14)
and fill with liquid until it
(14)
. Considerable amounts of liquid
(a)
.
Low quantity programme:
To prevent the pump from switching off earlier when used with low
quantity of water (e.g. washing machines or drip irrigation), the leakage
warning is only activated after 60 minutes.
Switching the pump on and off cyclically during the small quantity
program has no effect on the service life of the pump.
Use of washing machines:
Upon completion of the low quantity water supply cycle in washing
machines, the 60-minute operating interval of the low quantity programme
is automatically reset to normal operation of the pump and allows
a trouble-free use of the washing machine for > 60 minutes.
For continuous drip irrigation:
If the low quantity programme is to be used for more than 60 minutes,
the irrigation must be disrupted for at least 5 minutes before the end of
the 60 minute period. The low quantity programme can then be used
for a further 60 minutes.

4. MAINTENANCE

DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you maintain
the product.
To clean the filter [ Fig. M1 / M2 ]:
1. If applicable, close all the shutoff devices on the intake side.
2. Loosen the lid
(9)
of the filter chamber with the spanner
3. Remove the filter unit
(12)
/
(13)
vertically upwards.
4. Hold the cup
(12)
firmly, turn the filter
remove the filter 2 (bayonet fitting).
5. Clean the cup
(12)
under running water and clean the filter
e. g. with a soft brush.
6. Assemble the filter again in reverse order.
7. Start the pump (see 3. OPERATION).
To clean the check valve [ Fig. M3 / M4 ]:
CAUTION!
The pump must not be operated without the check valve.
1. If applicable, close all the shut-off devices on the intake side.
2. Open all tapping points so that the pressure escapes on the pressure
side. Now close the tapping points again so that the connected pipes
do not drain via the pump.
(14)
3. Loosen the cover
of the check valve with a suitable tool.
(15)
4. Remove the check valve
and clean it under running water.
(15)
5. Assemble the check valve
again in reverse order.
6. Start the pump (see 3. OPERATION).
5. STORAGE
To put into storage [ Fig. S1 ]:
The product must be stored away from children.
(11)
to position 0.
1. Push the on / off switch
2. Disconnect the pump from the mains.
3. Open the consumer on the pressure side.
4. Remove the connected hoses on the pressure and suction side.
5. Unscrew drain bolt
(1)
.
6. Tilt the pump to the suction and pressure side until water is no longer
discharged from either side.
7. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
(A)
provided.
(13)
counterclockwise 1 and
(13)