AlkaWay Ultrastream Undersink Kit Manual de instalação - Página 9

Procurar online ou descarregar pdf Manual de instalação para Sistemas de filtragem de água AlkaWay Ultrastream Undersink Kit. AlkaWay Ultrastream Undersink Kit 12 páginas.

7. Connecting UltraStream Unit
(see Quick Connect Connector Instructions page 2)
1. Lay the UltraStream onto its side.
2. Feed the white tube through the
hole in the side of the base, then
insert it into the quick connect
inside the base.
3. Turn the unit upright and insert
the size converter in the quick
connection in the top of the
UltraStream.
4. Insert the blue tube from the
faucet into size convertor quick
connection.

Leak Testing

1. Make sure cold water connector tap is turned off.
2. Turn water ON at mains or shutoff valve.
3. Turn on cold water connector tap and look for any leaks on the red tube.
If leaking, turn off the water. Check that the leaking tube is firmly inserted
into the conector. If there is still a leak, remove the tube from the Quick
Connection and re-cut the end of the tube.
4. Next turn ON the UltraStream faucet and check for leaks on the yellow and
blue tube connections.
Testing pH
How to test the pH of your water.
1. Add 2-3 drops of pH reagent to 30ml of water to be tested.
2. Mix well.
3. Compare the final colour of the solution to the enclosed colour chart to get
your reading (It's a good idea to use a white background).
4. pH Color Readings pH<7 Acidic, pH=7 Neutral, pH>7 Alkaline.

Setting the Flow Rate

How to get the correct water flow rate from your UltraStream.
1. Use the tap on the cold-water supply to control the flow rate.
2. A ¼" turn on the tap will adjust the flow from Fully On to Off.
3. Visually watch the flow from the faucet while adjusting the tap. Once you have
a moderate stream of water from the faucet. Record the time it takes to fill up
a 1 Liter (0.25 Gallon) bottle. If it is between 30-60 seconds then the flow rate
is now set to between 1-2 Liters per minute or 0.25-0.5 Gallons per minute.
9