alkitronic EAF Manual de operação e manutenção - Página 9

Procurar online ou descarregar pdf Manual de operação e manutenção para Bomba de água alkitronic EAF. alkitronic EAF 16 páginas. Battery powered torque multiplier

alkitronic EAF Manual de operação e manutenção

6. Mechanical operation

6.1
Safety instructions for tightening and loosening
Always observe local regulations and directives
when starting the tool. Always inspect power tool
as to its function and safety condition – never work
with damages tools or objects!
Beware freely rotating accessories (alkitronic®
DMA / STACO / STABI). Loose garments, long
hair, cables etc. must be kept outside the danger
zone / rotation range.
The alkitronic® EAF torque multiplier must never
be operated without supervision. An immediate
stopping must be possible at all times. Observe
safety distances.

6.1.1 Tightening and loosening

Always place the STACO/STABI completely and safely
on the bolt/nut. The support of the DMA to absorb
the reaction torque must always be safe and stable.
Please consult your alkitronic® partner for custom-
ized DMA solutions.
An incomplete or incorrect connection or support
will lead to the following when bolting:
- Possible overload fractures of the STACO / STABI
gear and even drive square
- Incorrect torque application
- Contusions or severe injuries caused by spun off
parts or splinters.
• An improper usage may also render all warranties null and
void.
Reaction torque
Never reach between DMA and support point. High
risk of injuries (contusion)!
battery powered torque multiplier
-
Direction of rotation
tightening
G
S
Incorrect
correct
Work steps
• Place alkitronic® EAF with STACO / STABI onto the bolt /
nut.
• The DMA must absorb the reaction torque on the level
of the STACO / STABI (S); a stable abutment (G) must be
provided.
• Always hold the torque multiplier perpendicular over
the bolt axis.
• Start bolting action.
• The tool will stop as soon as the set shut-off torque or
entered value has been reached.
Do not retighten bolts/nuts! Because the pre-
set torque is exceeded and it can lead to dam-
age to the torque multiplier or to the screw /
threaded bolt.
alkitronic® EAF model - before moving to the next bolt / nut:
Various torque multipliers from other manufacturers cannot
be removed from the bolt joint (torsional force).
No problem for the alkitronic® EAF model, with
integrated, fully-automatic release function. This
function enables a fast, secure "run free" of the reac-
tion arm (DMA) and also relieves torsional stresses
within the multiplier.
For Information:
When loosening the bolted connection, up to 20% higher
torque (loosening torque) may be required.
• Switch off motor
• Remove machine, place on next bolt/nut
• Start bolting process
9
Correct support
point only in the
marked area
Incorrect