alkitronic EFCip Manual de operação e manutenção - Página 8

Procurar online ou descarregar pdf Manual de operação e manutenção para Hardware informático alkitronic EFCip. alkitronic EFCip 16 páginas. Electric torque multiplier

Operation and Maintenance Manual
4.4.2 Bolting according to the combined torque/angle procedure (option)
Adjustment mode 2 - with/without automatic release function
Start Display
Enter
bolting program
Step 1
Enter
pre torque
Step 2
Enter
angle of rotation
Step 3
Enter
release angle
Step 4
Correction procedere:
push button and
return to step 1.
"OK" signalisation (bolting pro-
cess was flawless, e.g. rotation
angle is reached).
"nOK" signalisation flashes (faulty
bolting).
After a short time, the display
jumps to the next image.
Confirm input
Confirm input
Confirm input
Confirm input
No automatic release function:
Set angle to zero "0".
Once the values have been checked -
start bolting process.
Confirm resp. the acknowledgment is automatically.
Place on next bolt/nut and start
bolting process.
Probable reason: rotation angle is not reached. Bolted joint ex-
ceeds torque range of the used torque multiplier.
Check settings, repeat bolting.
Take into account relevant provisions of bolting. Use e.g. new
bolts etc.
8