Garmin GMR Fantom 56 Manual de instruções de instalação - Página 7

Procurar online ou descarregar pdf Manual de instruções de instalação para Equipamento marítimo Garmin GMR Fantom 56. Garmin GMR Fantom 56 19 páginas.
Também para Garmin GMR Fantom 56: Manual do Proprietário (12 páginas)

Garmin GMR Fantom 56 Manual de instruções de instalação
Wiring and Connection Considerations
It may be necessary to drill 32 mm (1
• When routing multiple cables through the same hole, you must route the network cable before the power and
ground cables because of the size of the network connector.
• You must apply marine sealant to the hole after the cables are in place to ensure a waterproof seal.
If you must make the routing hole in a visible location, decorative cable grommets can be purchased from
Garmin or a Garmin dealer (optional).
• If needed, you can trim the grommet to enable you to route multiple cables through the same hole.
• The optional grommet does NOT provide a waterproof seal. You must apply marine sealant to the grommet
after the cables are in place to ensure a waterproof seal.
When installing the cables, you should observe these considerations.
• Cutting the Garmin Marine Network cable is not recommended, but a field install kit can be purchased from
Garmin or a Garmin dealer if you must cut the network cable.
• The ground cable is not included, and must connect to a water ground location, not the negative terminal of
the battery
(Grounding the Radar,
• To ensure safety, appropriate tie-wraps, fasteners, and sealant should be used to secure the cable along the
route and through any bulkheads or the deck.
• You should not run cables near moving objects and high-heat sources, or through doorways and bilges.
• To avoid interference with other equipment, you should not run network and power cables parallel to other
cables, such as radio antenna lines or power cables. If this is not possible, the cables should be shielded with
metal conduit or a form of EMI shielding.
• You should install the power cable as close to the battery source as possible.
◦ If it is necessary to extend the power cable, you must use the appropriate wire gauge
Extensions,
page 9).
◦ Incorrectly extended runs of cable may cause the radar to malfunction due to insufficient power
transmission.
Connecting to Power Through the Voltage Converter
When connecting the power cable, do not remove the in-line fuse holder. To prevent the possibility of injury or
product damage caused by fire or overheating, the appropriate fuse must be in place as indicated in the product
specifications. In addition, connecting the power cable without the appropriate fuse in place voids the product
warranty.
Do not reuse any voltage converters from previous Garmin radar models, or third party voltage converters. Using
any converter other than one included with the radar may damage the radar or prevent it from turning on.
Some radar models require a voltage converter unit to properly power the device. If your model is packaged with
a voltage converter, it must be installed in order for your radar to function. If your model is not packaged with a
voltage converter, connect the power cable directly to the boat battery
When installing the voltage converter for an applicable radar model, observe these considerations.
• The voltage converter requires an input voltage of 10 to 32 Vdc.
• It is recommended to install the voltage converter as close as possible to the power source.
• Connecting the power cable for the voltage converter directly to the battery is recommended. If it is
necessary to extend the cable, the appropriate gauge of wire must be used for the length of the extension
(Power Cable Extensions,
1
/
 in.) holes for routing the power, network, or grounding cables.
4
page 10).
NOTICE
page 9).
WARNING
(Connecting to Power,
(Power Cable
page 9).
7