Fujitsu ABF22UIS-LV Manual de instruções - Página 16
Procurar online ou descarregar pdf Manual de instruções para Ar condicionado Fujitsu ABF22UIS-LV. Fujitsu ABF22UIS-LV 18 páginas. Floor/ceiling type
TROUBLESHOOTING
CHECK ONCE
Does not operate at all:
MORE
Poor cooling (or heating*)
performance:
The unit operates differ-
e n t l y f r o m t h e R e m o t e
Controller's setting:
If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION indicator lamp and the
TIMER indicator lamp fl ashes, and ECONOMY indicator lamp fl ashes fast. Immediately stop operation, turn off the electrical breaker
and consult authorized service personnel.
OPERATING TIPS
Instructions relating to heating (*) are applicable only to "HEAT & COOL MODEL" (Reverse Cycle).
Heating Performance*
This air conditioner operates on the heat-pump principle,
●
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi cient
heating performance is being produced, we recommend
you use this air conditioner in conjunction with another kind
of heating appliance.
●
Heat-pump air conditioners heat your entire room by recir-
culating air throughout the room, with the result that some
time may be required after fi rst starting the air conditioner
until the room is heated.
When Indoor and Outdoor Temperature are High*
When both indoor and outdoor temperatures are high during
use of the heating mode, the outdoor unit's fan may stop at
times.
The wired remote controller option is required to use the following function (**).
**Dual Remote Controllers (optional)
An additional remote controller can be added up to the maximum of 2 remote controllers. Either remote controller can control the air
conditioner. However, the timer functions cannot be used at the secondary unit.
**Group Control
1 remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings.
Group control cannot be used when using it by the multi type.
En-16
Symptom
●
Has the circuit breaker been turned off?
●
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
●
●
Is the timer operating?
●
Is the air fi lter dirty?
●
Are the air conditioner's intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat)
●
correctly?
Is there a window or door open?
●
●
In the case of cooling operation, is a window allowing bright
sunlight to enter? (Close the curtains.)
In the case of cooling operation, are there heating apparatus
●
and computers inside the room, or are there too many people
in the room?
●
Is the unit set for QUIET operation?
Are the Remote Controller's batteries dead?
●
●
Are the Remote Controller's batteries loaded properly?
Problem
Microcomputer-controlled Automatic Defrosting*
When using the heating mode under conditions of low out-
●
door temperature and high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this
unit is equipped with a microcomputer-controlled automatic
defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate brief-
ly (Max. 15 minutes).
During automatic defrosting operation, the OPERATION
indicator lamp (green) will fl ash.
After heating operation stops, if frost forms on the outdoor
●
unit, the unit will start automatic defrosting operation.
At this time, the outdoor unit will automatically stop after op-
erating for a few minutes.
Low Ambient Cooling*
When the outdoor temperature drops, the outdoor unit's fans
may switch to Low Speed, or one of the fans may stop inter-
mittently.
See page
—
9 to 10
—
—
6