Fujitsu ABY18LBAJ Manual de serviço - Página 14

Procurar online ou descarregar pdf Manual de serviço para Ar condicionado Fujitsu ABY18LBAJ. Fujitsu ABY18LBAJ 33 páginas. Inverter multi air conditioner floor console / under ceiling dual type
Também para Fujitsu ABY18LBAJ: Manual de serviço (32 páginas)

Fujitsu ABY18LBAJ Manual de serviço
The OPERATION, TIMER and SWING lamps operate
as follows according to the error contents.
Error contents
Indoor unit circuit board error
Indoor unit room temperature sensor wire opened
Indoor unit room temperature sensor wire short circuited
Indoor unit piping sensor wire opened
Indoor unit piping sensor short circuited
Serial error
Outdoor unit circuit board error or miswiring
between outdoor unit and indoor unit
Indoor unit fan error
Outdoor unit piping sensor
Outdoor unit outdoor temperature sensor error
Outdoor unit discharge temperature sensor error
Outdoor unit compressor temperature sensor error
IPM error
Current transformer error
Active filter module error
Compressor location error
Outdoor fan motor error
:
Fast flashing
Model : AOY24LMAL
2004.08.09
E R R O R
:
Slow flashing
DIP switch
DIP-SW
1
OFF
OFF
ON
OFF
OFF
ON
C O N T E N T S
OPERATION
(RED)
2 times
2 times
3 times
3 times
5 times
5 times
6 times
:
Off
2
3
OFF
OFF
ON
OFF
ON
OFF
13
Error display
TIMER
SWING
(GREEN)
(ORANGE)
3 times
4 times
5 times
9 times
10 times
11 times
12 times
13 times
14 times
Current
Model
(Max.)
16.5A
14.5A
AOY24LMAL
12.0A
9.5A