Fujitsu PRIMEPOWER 2500 Manual da plataforma de hardware - Página 43

Procurar online ou descarregar pdf Manual da plataforma de hardware para Servidor Fujitsu PRIMEPOWER 2500. Fujitsu PRIMEPOWER 2500 50 páginas. Enterprise servers
Também para Fujitsu PRIMEPOWER 2500: Manual (21 páginas)

Fujitsu PRIMEPOWER 2500 Manual da plataforma de hardware
Limitations and known bugs
No
Recommended actions
34
On PRIMEPOWER 200 (360MHz or higher) / 400(360MHz or higher)/600/650(except
SPARC64 V)/800/850(except SPARC64 V)/1000/1500(except SPARC64 V)/2000, both
syslog message and FMA message are displayed when a Memory 1 bit error(CE) occurs.
e.g.)
FJSV,SPARC64-IV: [ID 635115 kern.notice] Softerrors:
FJSV,SPARC64-IV: [ID 663638 kern.notice] Seen 0 Intermittent and 1 Corrected
Softerrors
FJSV,SPARC64-IV: [ID 909492 kern.notice] from SIMM C0S00-SLOT#B00 (synd =
0x13, addr = 0x75268280).
FJSV,SPARC64-IV: [ID 805745 kern.notice] Softerror: Persistent ECC Memory Error
FJSV,SPARC64-IV: [ID 306888 kern.notice] Corrected SIMM C0S00-SLOT#B00
FJSV,SPARC64-IV: [ID 518845 kern.notice] Detected by Module ID = 0x87 (135)
unix: [ID 618185 kern.notice] NOTICE: Scheduling removal of page
0x00000000.75268000 fmd: [ID 441519 daemon.error]
SUNW-MSG-ID: SUN4US-8000-7D, TYPE: Fault, VER: 1, SEVERITY: Minor
EVENT-TIME: Mon Feb 21 21:26:51 JST 2005
PLATFORM: FJSV,GPUSC-M, CSN: -, HOSTNAME: colm2
SOURCE: cpumem-diagnosis, REV: 1.3
EVENT-ID: aaf47b25-cfd2-4984-f598-e81bcbba274f
DESC: The number of single bit errors associated with this memory module continues
to exceed acceptable levels. Refer to
http://www.fujitsu.com/global/services/computing/server/unix/prmpwr_msg/SUN4US
-8000-7D for more information.
AUTO-RESPONSE: An attempt will be made to remove this memory page from
service.
IMPACT: Total system memory capacity will be reduced as pages are retired.
REC-ACTION: Schedule a repair procedure to replace the affected memory module.
Use fmdump -v -u <EVENT_ID> to identify the module.
Ignore these syslog messages. They have no impact on the system.
35
System does not display CPU error messages via FMA if the CPU at fault has not been
replaced; even if the CPU detected the same error previously. This problem only happens
on systems installed with SPARC64 V.
This is just a messaging issue. It has no impact on the system as such.
36
After an upgrade to install Solaris 10, the following message is displayed when format
(1M) command is executed.
# format
Unknown controller 'MD21' - /etc/format.dat (xx)
Searching for disks...done
There is no impact on the system. The message is not displayed when the following
entries are removed from /etc/format.dat.
disk_type = "XXXX" \
: ctlr = MD21 \
: ncyl = XXXX : acyl = X : pcyl = XXXX : nhead = X : nsect = XX \
: rpm = XXXX : bpt = XXXXX
Remarks
37