Fujitsu Primergy RX100 S4 Manual de início - Página 2

Procurar online ou descarregar pdf Manual de início para Servidor Fujitsu Primergy RX100 S4. Fujitsu Primergy RX100 S4 8 páginas.
Também para Fujitsu Primergy RX100 S4: Manual do suplemento de serviço (43 páginas)

Fujitsu Primergy RX100 S4 Manual de início
4
Checking location before installing the server
For details on installing the rack, refer to the "Rack Instal-
lation Guide" and the manual provided with the rack.
n Conditions
When installing this server, avoid the following areas.
- Humid, dusty, or oily areas
- Poorly ventilated areas
- Areas close to fire or other sources of heat
- Areas close to water
- Areas close to direct sunlight or near heating appliances
- Areas with a temperature of below 10°C or above 35°C
- Areas with humidity of less than 20% or more than 80%
- Salty areas
- Areas where corrosive gas is generated
- Areas where cables become trip hazards
- Areas where strong magnetic fields are generated, such
as near TVs and speakers
- Areas where the server is not stable and could tip over
and hurt somebody
- In dusty areas, dust will stick to the front and backside of
the server for a short period of time.
Since it causes failure, changing the installation place is
recommended.
- Noise levels of this server are measured at 46dB.
When the server is installed to e.g. an office use the
server with careful consideration to the environment.
- Be sure to fix the rack and attach stabilizers to the base
of the rack.
n Installing the server to the rack
1
Open both the front and rear doors of
the rack.
2
Attach M5 rack nuts to the rack.
Insert the rack nut in the rack's 2nd hole position.
(counting up from the base of the server).
��������������
���������������
��������������
������������
����������
3
Pull out the inner rail from the slide
rail.
Pull out the inner rail pushing the lock on the far
side.
����������
4
Attach the inner rail on the right and
left side of the server.
Set the screws on the server side in the holes of the
rail (1), and slide the rail forward to fix it (2).
��������������������
���
5
Insert the tags of the slide rail to the
second hole from the bottom of the
server.
���������������������������
���������������
�����������
2
����������
�������������
����������
�������������������������
���