Fujitsu ETERNUS AF Series Manual de configuração - Página 23
Procurar online ou descarregar pdf Manual de configuração para Armazenamento Fujitsu ETERNUS AF Series. Fujitsu ETERNUS AF Series 38 páginas. Hybrid storage systems, all-flash arrays, power synchronized unit
Também para Fujitsu ETERNUS AF Series: Manual de configuração (16 páginas), Precauções de segurança (12 páginas)
Chapter 8
Installing Drivers and Setting Up the Server
8.3
Installing the Multipath Driver
●
For a virtual FC adapter
Set the parameter as shown in the following table.
Target server
VIOS
VIOC
*1: Recommended value = 1024 ¸ (number of Fibre Channel ports that are connected to a single CA port)
(Round the result down)
•
Use the minimum value of the driver if the actual result is lower.
•
To achieve maximum system performance, this value can be changed according to the server load
and the peak operating times.
•
The number of simultaneous command executions per CA port for the ETERNUS DX/AF is limited to
1024. This value is used by multiple servers that share the CA port. A maximum of 1024 commands
can be executed per CA port.
8.3
Installing the Multipath Driver
•
When the standard multipath driver is used
Install FJSVmpio by following the readme file provided with FJSVmpio.
When the ETERNUS Multipath Driver is used
•
Install the ETERNUS Multipath Driver by following the manual provided with the ETERNUS Multipath Driver.
8.4
Installing the FJspio Package
FJspio is used to register the ETERNUS DX/AF on the AIX server's ODM.
The FJspio package must be installed in both of the following cases:
Single-path connection is used
•
•
Multi-path connection is configured using VxVM
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for AIX
Parameter
Setting target
num_cmd_elems
fcs
init_link
fcs
dyntrk
fscsi
fc_err_recov
fscsi
num_cmd_elems
fcs
fc_err_recov
fscsi
Dyntrk
fscsi
23
Copyright 2018 FUJITSU LIMITED
Setting value
Remarks
Arbitrary (*1)
—
(Up to 1024 for each FC
port of the ETERNUS
DX/AF)
auto
yes
fast _fail
Arbitrary (*1)
—
(Up to 1024 for each FC
port of the ETERNUS
DX/AF)
fast _fail
yes
P3AM-3782-23ENZ0